During data transfer, User information, Range – Leica Geosystems Leica DISTO plus - Manual User Manual

Page 13: Increased range, Reduced range / increased measuring time, Rough surfaces, Transparent surfaces

Advertising
background image

12

User Information

Leica DISTO™ plus 1.0.0 GB

de

GB

fr

it

es

nl

ja

Press briefly to confirm that the correct line was
drawn. The line is then drawn thicker with the
measurement dispayed.
Press briefly to clear a wrong line.

.

Is the measurement is still displayed in the Leica DISTO™
plus, it ca
n be transferred again by pressing the correct
arrow key.
Other functions are described in the manual of the
software used.

During data transfer

As long as there is no confirmation of a successful data
transfer from the Pocket PC or PC, no new measurement
can be triggered.

Appears and "240" blinks, if after 2 seconds no
data transfer occurs.
Press briefly to acknowledge the display. Repeat
measurement and data transfer.

Remark to the software
The two free software progams "PlusDraw" and "PlusXL"
are included to demonstrate the basic applications of the
Leica DISTO™ plus and are designed to perform simple

tasks (spatial drawings with measurements , data transfer
into an Excel table etc.)
Leica Geosystems gives no warranty on the free software
nor on their functionality and does not offer any support.
Leica Geosystems is not liable for any damage resulting
from the use of the free software and is not obligated to
make corrections on them or to develop additional
functions for them (updates, upgrades etc.).
There are a number of commercially available software
programs that provide the required functions. Please visit
our homepage www.disto.com for details.

User Information

Range

In daylight (outdoors) always work with a laser viewfinder
(see page 13). If neceesary, shade the target. If required,
use a target plate.

Increased range:
At night, at dusk and when target area is in the shade.

Reduced range / increased measuring time:
Against mat and dark surfaces (also plants and trees) a
reduction of the range may occurs as well as an increase
in measuring time.

Rough surfaces

On a rough surface (e.g. coarse plaster) measure against
the centre of the illuminated area.
To avoid measuring to the bottom of plaster joints:
Use target plate, 3M "Post-it" or board.

Transparent surfaces

To avoid measuring errors, do not measure towards
colorless liquids (e.g. water) or (dust free) glass, styropor.
or similar semi- permeable surfaces. For materials and
liquids unfamiliar to you always take a trial measurement.

)

When aiming through panes of glass, or if there

are several objects in the line-of-sight erroneous measure-
ments can occur.

Advertising