Communication Journal (COMM. JOURNAL)

The Communication Journal (COMM. JOURNAL) lets you verify if transmission or polling was successfui or

not. You may seiect the printout condition (Off/Aiways/inc. oniy) in Function 8-1, see page 41.

Sample COMM. JOURNAL

****************************_QOMM. JOURNAL- ********

da

TE 08-DEC-1993 ***** TIME 12:00 ***** P.l

(1)

MODE = MEMORY TRANSMISSION

FILE NO. = 079 {4)

(2)

(3)

START=08-DEC 11:50

END=08-DEC 12:00

(5)

(6)

(7)

(8}

(9)

(10)

(11)

(12)

NO.

COM

ABBR/NTWK

STATION NAME/

TELEPHONE NO.

PAGES

PRG.NO.

PROGRAM NAME

RLY

001

OK

[01]

SERVICE DEPT.

001/001

002

OK

[02]

SALES DEPT.

001/001

003

OK

[03]

ACCOUNTING DEPT.

001/001

004

INC

B

021 111 1234

000/001

(13)

-PANASONIC

Explanation of Contents

(1) Indication of communication mod©
(2) Starting time of communication
(3) Ending time of communication
(4) Fiie number

(5) Communication number

001 to 255 (When the communication is stored into memory, a file number
is assigned for each communication.)

(6) Communication result

"OK" indicates that the transmission was successful.
"R-OK” indicates that the transmission to the Reiay Station was successfui.

"iNC" indicates that the transmission was not completed.

(7) Abbreviated number or B mark

S

mark indicates dialed by direct number dial.

(8) Recorded name in One-Touch,

ABBR. or direct dialling number

(9) Number of pages transmitted or

received

The 3-digit number Is the number of pages successfully transmitted or

received.
When the documents are stored into memory, two 3-digit numbers will appear.
The first 3-digit number represents the number of pages successfuliy
transmitted. The second 3-digit number represents the total number of pages
that were attempted to be transmitted.

(10) Program key number
(11) Recorded name in the Program key
(12) Relay Station’s ABBR. NO./Network

Address

(13) Own LOGO

(14) Own ID number

(15) Own Character ID

Up to 25 characters

Up to 20 digits

Up to 16 characters

114