Cisco IAD2430 User Manual

Page 51

Advertising
background image

3-15

Cisco IAD2430 Series Integrated Access Devices Hardware Installation Guide

OL-4234-06

Chapter 3 Installing Cisco IAD2430 Series IADs

Installing the Ground Connection

Warning

The importance of proper grounding cannot be overemphasized. It will minimize the potential for
damage to your system and maximize safety at the system site. We recommend you consult a licensed
electrician or your local electric utility company if you have any questions.
Statement 269

Warning

A ground wire must always be a single piece of wire. Never splice two wires together for a ground.
Corrosion and weathering can lead to a poor connection at the splice, making the ground ineffective
and dangerous.
Statement 270

Warning

Use copper conductors only. Statement 1025

Warning

Installation of the equipment must comply with local and national electrical codes. Statement 1074

You must connect the chassis to a reliable earth ground; the ground wire must be installed in accordance
with local electrical safety standards.

For NEBS-compliant grounding, use size AWG 6 (13 mm

2

) wire and the ground lug provided in the

accessory kit.

For NEC-compliant grounding, use size AWG 14 (2 mm

2

) or larger wire and an appropriate

user-supplied ring terminal.

For EN/IEC 60950-compliant grounding, use size AWG 18 (1 mm

2

) or larger wire and an

appropriate user-supplied ring terminal.

To ground the chassis, follow these steps:

Step 1

Locate a suitable ground location.

Tip

Use a multimeter to measure the resistance between various ground locations, such as the following:

Between the ground of a junction box (outlet) and the ground of a power tap

Between the ground of a junction box and a metal water pipe

Between the Cisco IAD chassis and the ground of a power tap

Between the Cisco IAD chassis and the ground of a junction box

A good ground connection should read between 0.0 and 0.5 ohm.

Step 2

Strip one end of the ground wire to the length required for the ground lug or terminal.

For the NEBS ground lug—approximately 0.75 inch (20 millimeters)

For user-provided ring terminal—as required

Step 3

Crimp the ground wire to the ground lug or ring terminal, using a crimp tool of the appropriate size. (See

Figure 3-13

.)

Advertising