Connecting Cables

Warning

This equipment contains a ring signal generator (ringer), which is a source of hazardous voltage. Do
not touch the RJ-11 (phone) port wires (conductors), the conductors of a cable connected to the RJ-11
port, or the associated circuit-board when the ringer is active. The ringer is activated by an incoming
call.
Statement 1042

Procedure

Step 1

Connect the RJ-21 cable from the analog voice multiport to the distribution panel. See

Figure 3-28

.

Figure 3-28

Analog Voice Connection

Step 2

Use the strap to secure the cable in place.

Connecting the Digital Voice Port to a T1/E1-PBX

To connect the digital voice port to a digital PBX, use the procedure in this section.

Cable

Use an RJ-48 T1/E1 cable (not included).

Procedure

Step 1

Connect the RJ-48 T1/E1 cable to the T1/E1 port. See

Figure 3-29

.

88968

RJ-21 cable

Distribution panel