Manual No. M13-167-B0614

All units of measurement are displayed according to either the CGS system or the SI system.

1.

Viscosity appears in units of centipoise (cP), Poise (P), milliPascal-seconds (mPa•s) or

Pascal-seconds (Pa•s) on the DV2T Viscometer display or centistokes (cSt) or millimeter

squared per second (mm

2

/sec).

2.

Shear Stress appears in units of dynes/square centimeter (D/cm

2

) or Newtons/

square meter (N/m

2

)/or Pascals (Pa).

3.

Shear Rate appears in units of reciprocal seconds (1/sec).

4.

Torque appears in units of dyne-centimeters or Newton-meters (shown as percent “%” in

both cases) on the DV2T Viscometer display.

5.

Density appears in units of grams/cubic centimeter (g/cm

3

) or kilograms/cubic

meter (kg/m

3

).

Note:

To change CGS to SI units on the display - see Section IV.3: Global Settings.

The equivalent units of measurement in the SI system are calculated using the following

conversions:

SI

CGS

Viscosity:

1 mPa•s

= 1 cP

Shear Stress: 1 Newton/m

2

= 10 dyne/cm

2

Torque:

1 Newton•m = 10

7

dyne•cm

References to viscosity throughout this manual are done in CGS units. The DV2T Viscometer

provides equivalent information in SI units.

I.1 Components

Please check to be sure that you have received all components, and that there is no damage.

If you are missing any parts, please notify Brookfield Engineering or your local Brookfield agent

immediately. Any shipping damage must be reported to the carrier.

Components

Part Number

Quantity

DV2T

DV2T Extra

DV2T Viscometer

varies

1

1

Model G Laboratory Stand

Model Q Laboratory Stand

MODEL G

MODEL Q

1

ш

ш

1

Spindle Set with Case

DV2TLV set of four spindles

DV2TRV set of six spindles (#2 - #7)

DV2THA / HB set of six spindles (#2 - #7)

varies

SSL

SSR

SSH

1

or
or

1

For Cone/Plate versions: a spindle wrench (SP-23), one cone spindle (CPA-XXZ), a sample
cup (CPA-44YZ) replace the spindle set.

Power Cord

DVP-65 for 115

DVP-66 for 230

DVP-65

DVP-66

1

or

1

RTD Temperature Probe

DVP-94Y

1

1

Guard Leg

DV2TLV

DV2TRV

B-20Y

B-21Y

1

or

1

Carrying Case

PG Flash Software

RheocalcT Software

USB Flash Drive

Screen Cloth w/case

Stylus
Operating Manual

Shipping Cap

Screen Protector Kit

DVE-7Y

CD-PROGA

DVP-202AY

GV-1044

GV-1045

GV-1043

M13-167

N/A

GV-1019

1
1

ш

1
1
1
1
1
1

1
1
1
1
1
1
1
1
1

Advertising