KEYENCE OP-85135 User Manual

KEYENCE Sensors

Advertising
background image

Attachment / Slit Plate / Polarizing Filter for the PZ-G Series
Instruction Manual

List of attachments / polarizing filters

A slit plate and polarizing filter can be installed in the thrubeam type sensors (PZ-G51/G52 Series).
Mount the slit plate and polarizing filter on the main body after assembling the attachment using the
following procedures. (The slit plate and polarizing filter can be mounted simultaneously.)

Before use, be sure to remove the protective seal from both sides of the polarizing filter.

OP-85136 (attachment for square type sensors)

* The slit plate and polarizing filter are optional.

Assembling the attachment

Mounting onto the main body

OP-85135 (attachment for threaded type sensors)

* The slit plate and polarizing filter are optional.

Assembling the attachment

Mounting onto the main body

Mount the slit plate and polarizing filter at the following position.

Receiver .................................................. Upper portion

PZ-G51 Series transmitter ...................... Upper portion

PZ-G52 Series transmitter ...................... Upper/lower portions

When mounting the slit plate and polarizing filter on the thrubeam type sensors (PZ-G51/52
Series) make sure the transmitter and receiver are mounted facing the same direction.
In addition, if a sensor is mounted adjacent to the existing one, mount the sensors so that
they face the opposite direction.

Example: When interference prevention is carried out for 4 sets

OP-85137 (slit plate set)

Three types of slit plates with varying widths are available. Select according to your detection purposes
from the following list.

Name

Contents

Model No.

Attachment A

Square type attachment

× 2 pcs.

OP-85136

Attachment B

Threaded type attachment

× 2 pcs.

OP-85135

Slit plate set

0.5 mm, 1 mm, 2 mm

× 3 pcs. each

OP-85137

Polarizing filter A (red)

Red polarizing filter

× 2 pcs.

OP-85138

Polarizing filter B (infrared)

Infrared polarizing filter

× 3 pcs.

OP-85139

Important

Attachment

Slit plate

Polarizing filter

Cover

Attachment with the slit plate
and polarizing mounted

Photoelectric sensor head

The slit plate can be
mounted vertically.

When removing the cover,
use a screwdriver to hold
the hook down.

Attachment

Slit plate

Polarizing filter

Cover

Attachment with the slit plate and
polarizing filter mounted

Photoelectric sensor head

The slit plate can be
mounted vertically.

* When removing the cover,
use a screwdriver to hold
the hook down.

Contents

Slit plate

Slit plate + polarizing filter

Slit plate size (mm)

0.5

Ч5.0

1.0

Ч5.0

2.0

Ч5.0

No slit

plate

0.5

Ч5.0

1.0

Ч5.0

2.0

Ч5.0

Color of slit plate

Black

Blue

Gray

Black

Blue

Gray

Detecting

distance

(m)

PZ-G51

Series

1

2.5

5

9

0.5

1.5

3

PZ-G52

Series

2.5

5.5

10

15

1

2

5

Note

Mount only
on the upper
portion

Mount on
both the
upper/lower

PZ-G51 transmitter

PZ-G52 transmitter

Mount only
on the upper
portion

PZ-G51/G52 receiver

Receiver

Transmitter

Receiver

Transmitter

Transmitter

Receiver

Transmitter

Receiver

96M00080

Advertising