KEYENCE FS-22X User Manual

Instruction manual, Dual digital fiber sensor, Safety precautions

Advertising
background image

1

Dual Digital Fiber Sensor

FS-V22/22G/22R(P)/20R/22X

Instruction Manual

Read this manual before using the product in order to achieve
maximum performance.
Keep this manual in a safe place after reading it so that it can be
used at any time.

1. Safety Precautions

WARNING

• This product is just intended to detect the object(s). Do not use this

product for the purpose to protect a human body or a part of human
body.

• This product is not intended for use as explosion-proof product. Do

not use this product in a hazardous location and/or potentially explo-
sive atmosphere.

• This product is a sensor of DC power supply type. Do not apply AC

power. The product may explode or burn if 100 VAC or a higher volt-
age is applied.

UL Certificate
This product is an UL/C-UL Listed product.
• UL File No. E301717
• Category NRKH, NRKH7
• Enclosure Type 1 (Based on UL50)

Be sure to consider the following specifications when using this product
as an UL/C-UL Listed Product.
• Use the power supply with Class 2 output defined in NFPA70 (NEC:

National Electrical Code).

• Use with the over current protection device which is rated 30V or more

(rated 40V or more for NPN output type) and not more than 2A.

Check that all the accessories are ready before use.
Accessories

Instruction manual (x1) End units (x2)
Expansion Sticker (x1)

2. Part Names

Operation indicator*

Digital
monitor

Preset value (PV)
green indicator

Current value
(CV) red indicator

Dust cover

Fiber lock lever

Set button

Manual
button

Mode button

Expansion protective cover

Expansion connector

Output selector

Cable

3. Amplifier Expansion

Up to 16 expansion units can be connected
to each main unit.
1) Remove the expansion protective cover

from the main unit.

2) Mount each amplifier to the DIN rail.

3) Press the two claws of each expansion

unit to the grooves on the main unit
until the claws snap.

4) Mount the end units to the left- and

right-hand sides of the whole amplifi-
ers in the method shown in the figure
at step 2.

5) Check that the amplifiers are securely sand-

wiched by the end units. Use a Phillips screw-
driver and securely tighten the screws on the
end units (i.e., two screws on each end unit).

4. Connecting Fiber Unit

Fiber insertion sign

1) Open the dust cover in the direction

shown by arrow

➀.

2) Move down the fiber lock lever in the

direction shown by arrow

➁.

3) Insert a fiber unit into the fiber inser-

tion holes to a length of the fiber in-
sertion sign (i.e., approximately 14
mm).

4) Move up and return the fiber lock lever

in the direction shown by arrow

➃.

Note:If a thin fiber unit is used, an adapter provided with the thin fiber unit

will be required.
Unless the right adapter is connected, the thin fiber unit will not
detect targets correctly.

Cable outer dia.

Adapter

Appearance

ø1.3

Adapter A

ø1.0

Adapter B

• To connect the coaxial reflective type fiber unit to the amplifier, connect

the single-core fiber to the transmitter side, and connect the multiple-
core fiber to the receiver side.

Single-core fiber

Multi-core fiber

Transmitter

Receiver

• To remove the amplifiers added, take the steps opposite to the mount-

ing procedure.

• Put the provided sticker close to the sensor.

Note • The FS-V22/22G/22R(P)/20R/22X incorporates a mutual

interference prevention function, thus allowing the close mounting
of a number of fiber units in the following modes.

Power mode

Number of

units connected

FINE

4

TURBO

8

SUPER
TURBO

8

ULTRA

TURBO

8

5. I/O Cricuit

Refer to the following I/O circuit diagram when connecting the unit to pe-
ripheral devices.
FS-V22/22G/22R/22X

FS-V22RP

0 V

Max. 20mA

DC 5 to 40V

(Control output)

Load

Black

Photoelectric

sensor main circuit

Overcurrent

protection circuit

DC 12 to 24V

Max. 20mA

0V

(Control output)

Load

Black

Photoelectric

sensor main circuit

Overcurrent

protection circuit

* The operation indicator of the FS-V22X (infrared model) will not be lit.

96M11224

Advertising
This manual is related to the following products: