WARNING

Accessories

• Instruction manual (x 1)
• Mounting bracket [FS-V11(P) only]
• End unit (x 2) [FS-V12(P) only]
• Directions (x 1) [FS-V12(P) only]

SAFETY PRECAUTIONS

• This product is just intended to detect the object(s). Do not use

this product for the purpose to protect a human body or a part
of human body.

• This product is not intended for use as explosion-proof

product. Do not use this product in a hazardous location and/or
potentially explosive atmosphere.

SPECIFICATIONS

1. The response time varies depending on the number of expansion units connected.
2. The orange LED is normally part of the bar graph LED monitor. It is used as a calibration

indicator during the setting of the sensitivity.

3. When several units are connected, the allowable ambient temperature changes depending

on the following conditions. To connect several units, be sure to mount them to a DIN rail
(metal DIN rail). Make sure that the output current is 20 mA. max.
• When 3 to 10 units are connected: -10 to +50 °C (14 to 122°F)

• When 11 to 16 units are connected: -10 to +45 °C (14 to 113°F)

Model

NPN output

FS-V11

FS-V12

FS-V10

PNP output

FS-V11P

FS-V12P

Light source

Red LED

Response time

250 µs (FINE)/500 µs (TURBO)/

410 µs to 1.7 ms

1.

1 ms (SUPER)

Operation mode

LIGHT-ON/DARK-ON (switch selectable)

Indicators

Output indicator: Red LED

Digital LED monitor: Red LED

Bar graph LED monitor: Green/Orange LED

2.

Calibration indicator: Orange LED

2.

Timer function

OFF-delay: 40 ms, 10 ms

Timer OFF

Control output

NPN or PNP open-collector 24V 100mA max.

Residual voltage: 1V max.

Protection circuit

Reverse polarity protection, Over-current protection,

Surge absorber

Power supply voltage

12 to 24 VDC ±10%, Ripple (P-P) 10% max, Class 2

Current consumption

50 mA max.

Ambient illumination

Candescent lamp: 10,000 lx max., Sunlight: 20,000 lx max

Ambient temperature

3.

-10 to +55°C (14 to 131°F), No freezing.

Relative humidity

35 to 85%, No condensation

Vibration

10 to 55 Hz, 1.5 mm double amplitude in X, Y and

Z directions for two hours

Shock immunity

500 m/s

2

in X, Y and Z directions, three times each

Housing material

Body/Cover: Polycarbonate

Weight

Approx. 80 g

Approx. 45 g

Approx. 20 g

(including 2-m cable)

SELECTING DISPLAYED DATA

Displaying received light intensity

Received light intensity is displayed approximately 4000 is the
maximum setting.

Note: The MAX and MIN values vary depending on the fiber unit
connected.

Displaying excess gain

Received light intensity is converted by defining the setting value as
100 P (%).

Displaying the hold value

The peak value or the minimum value of the received light intensity or
excess gain is displayed.
The setting of the output selector switch determines whether the peak
value or the minimum value is displayed.

PART NAMES AND FUNCTIONS

FS-V11(P)
(Main unit)

SUPER

D. ON

MODE

SET

L. ON

TURBO

FINE

SET

40ms

OFF

10ms

SET

MODE

SUPER

D. ON

MODE

SET

L. ON

TURBO

FINE

SET

40ms

OFF

10ms

Operation indicator
(Red)

Bar graph LED
monitor

Calibration indicator
(Orange)

Digital LED monitor

Auto SET
button

Manual
button

MODE
button

Output
selector switch

DARK-ON

LIGHT-ON

3-core
cable

FS-V12(P)
(Expansion unit)

Expansion
connector

Single-core
cable

Output selector switch

Display

Hold value

LIGHT-ON

Peak-hold value

DARK-ON

Bottom-hold value

Displaying the setting value

Press

or

once while the received light intensity is displayed.

The setting value flashes for 2 seconds, and then the received light
intensity appears once more.

Note: To change the setting value, press

or

while the setting

value is flashing.

MODE

MODE

MODE

MODE

Press this
button once.

Received light intensity

Hold display
(Light intensity)

Press this
button once.

Display
changes
alternately.

Display
changes
alternately.

Press this
button once.

Press this
button once.

Hold display
(Excess gain)

The display changes every time the MODE button is pressed.

Excess gain display (%)

SUPER

D. ON

MODE

SET

L. ON

TURBO

FINE

SET

40ms

OFF

10ms

Expansion
connector

FS-V10
(Expansion unit)

PRECAUTIONS ON REGULATIONS AND STANDARDS

UL Certificate

This product is an UL/C-UL Listed product.
• UL File No. E301717
• Category

NRKH,NRKH7

• Enclosure

Type 1 (Based on UL50)

Be sure to consider the following specifications when using this
product as an UL/C-UL Listed Product.
• Use the power supply with Class 2 output defined in NFPA70 (NEC:

National Electrical Code).

• Power supply/ Control input/ Control output circuits shall be

connected to a single Class 2 source only.

• Use with the over current protection device which is rated 24V or

more and not more than 2A.

Hybrid Fiberoptic Sensors

FS-V11(P)/12(P)/10

Instruction Manual

96M11225

Read this manual before using the product in order to achieve
maximum performance.
Keep this manual in a safe place after reading it so that it can be used
at any time.