Part Names

Amplifier Unit

There are two types of amplifier units.
• PX-10/10P (above): Uses a cable length of 2 m and can handle external input.
• PX-10C/10CP (connector type): Connects to the power source with a socket cable.

Input/Output Circuit

PX-10 (NPN output)

PX-10P (PNP output)

PX-10C (connector type NPN output)

PX-10CP (connector type PNP output)

Socket Cables for PX-10C/10CP (Optional)

OP-75721 (cable length 2 m)

OP-75722 (cable length 2 m)

Relationship between connector pin numbers and cable core wires

Information in the following table is the same for OP-75721 and OP-75722.

Note

When connecting the L-shaped cable (OP-75722) to the amplifier unit, face the
connector for the cable towards the amplifier unit in the direction shown in the following
diagram and lock it into place. Note that the connector portion cannot be reversed.

Precautions on Installation

Connecting the Sensor Head to the Amplifier Unit

Note

The sensor is not guaranteed under the conditions of the warranty if the sensor head
is not connected correctly using the procedure described above.

The sensor is not guaranteed under the conditions of the warranty if dust or dirt
attaches to the packing for the sensor.

If the sensor head cannot be inserted easily, fully remove any dirt or dust from the
amplifier unit and apply silicon grease to the opening.

1

Grasp the cap for the sensor head connector and insert the connector straight
in the direction shown in the diagram.

SET

UP/DOWN

MODE

DSC indicator

Operation status indicator

(detection output)

Operation status indicator

(alarm output)

Digital monitor

Head release lever

button

SET

buttons

UP/DOWN

button

MODE

Head installation
holes

Sensor head connector
receptacle

Load

0 V

12–24 V DC

Brown

White (Alarm output)

Light sensor circuit

5–40 V DC

5–40 V DC

Overcurrent

protection circuit

Blue

Black (Detection output)

Load

3.3 V DC

Blue

Pink (input)

(Short-circuit current
1 mA max.)

PLC, etc.

0 V

Main sensor circuit

0 V

12–24 V DC

Brown

White (Alarm output)

Light sensor circuit

Blue

Black (Detection output)

Load

Overcurrent

protection circuit

Load

Brown

Pink (input)

(Short-circuit
current
2 mA max.)

PLC, etc.

12–24 V DC

Main sensor circuit

Load

0 V

12-24 V DC

Pin q

Pin w (Alarm output)

Light sensor circuit

5-40 V DC

5-40 V DC

Overcurrent

protection circuit

Pin e

Pin r (Detection output)

Load

Connector

pin position

w

q

e

r

0 V

12-24 V DC

Pin q

Pin w (Alarm output)

Light sensor circuit

Pin e

Pin r (Detection output)

Load

Overcurrent

protection circuit

Load

Connector

pin position

w

q

e

r

Warning

This product is used to detect targets. Do not apply the product to
safety circuits for human protection.

This product is not of explosion-proof construction. Do not use the
products in places with flammable gas, liquid, or dust.

This product is a sensor of DC power supply type. Do not apply
AC power. Application of the AC power may lead to explosion or
fire.

Connector pin no.

Wire casing color

Connection

Brown

12 to 24 V DC

White

Alarm output

Blue

0 V

Black

Detection output

Connector

pin position

w

e

q

r

Amplifier unit

Sensor head
connector

Hold the cap by
the sides.