KEYENCE PZ-V/M User Manual

Pz-v/pz-m, Instruction manual, Self-contained photoelectric sensor

Advertising
background image

1

Self-contained
Photoelectric Sensor

PZ-V/PZ-M

Instruction Manual

Read this manual before using the product in order to achieve maximum perform-
ance.
Keep this manual in a safe place after reading it so that it can be used at any time.

96M11228

Part Names

Operation indicator

Sensitivity
adjustment trimmer

Operation
indicator

Front side

SET button

UP button

Digital
monitor

DOWN
button

Rear side

PZ-M

PZ-V

I/O Circuit

Circled numbers 1 to 4 represent the connector pin numbers.

DC12 to 24V

0V

3

1

Photoelectric sensor

main circuit

Brown

Blue

PZ-M51(Receiver)/M61/M11/M31/V11/V31

PZ-M51P (Receiver)/M61P/M11P/M31P/V11P/V31P

Function

Operation

Description

Distance

display

Display
selection

Key-lock

Key-lock
cancel

1

2

PZ-M51(P) (Transmitter)

Photoelectric sensor

main circuit

Overcurrent

protection circuit

Brown

1

2

4

3

12 to
24 VDC

Pink

Load

0 V

Blue

Output
control

Black
Output

DARK-ON mode 12 to 24 VDC
LIGHT-ON mode 0 V

(

)

*

*

Photoelectric sensor

main circuit

Overcurrent

protection circuit

4

1

2

3

12 to
24 VDC

Pink

Output DARK-ON mode 12 to 24 VDC
control LIGHT-ON mode 0 V
0 V

Blue

Brown

(

)

Load

Black
Output

Operation

Procedure

Adjustment

Sensitivity Adjustment

Operation

Procedure

Adjustment

Operation

Procedure

Adjustment

1

Pass a target through the optical axis while
pressing the SET button.

2

Confirm that “

” flashes on the monitor.

Release the SET button. The preset value flashes
several times before the normal display appears.

1

2

With no target, press the SET button and release
it. “

” and the current distance flash alternately.

With the target in place, press and release the
SET button. The preset value flashes several
times before the normal display appears.

Confirm that “

” flashes on the monitor.

With no target, press the SET button for three
seconds or more.

Release the SET button. The preset value flashes
several times before the normal display appears.

1

2

3

3

Note:If the green LED turns off or " - - - " flashes after the calibration, the sensitivity has no
allowance. In such a case, adjust the sensor head position, and calibrate again.

PZ-V (Digital type)

Detect a moving target (Fully-automatic calibration)

To detect a stationary target (Two-point calibration)

To obtain maximum sensitivity (Maximum sensitivity setting)

Fine sensitivity adjustment

When the or button is pressed and released, the numerical value flashes (approx. 2
seconds). This is the preset value. If the or button is pressed again while the preset
value flashes, the preset value can be increased or decreased.

When the or button is held down for 3 seconds or more, the preset value increases/
decreases continuously.

Other functions

Distance display

• The greater the distance between the target and the sensor head, the larger the displayed value

becomes.

• If the target or background is out of the detectable range, is

displayed.

Note 1

:

The distance value indicates a reference value only. It is not an absolute distance.

Note 2

:

If the target approaches the sensor head closer than the specified range, the

displayed value may increase.

Thrubeam type

Proce-
dure

Operation

Trimmer Indicators

Adjustment

Max.

Max.

Max.

Green

Orange

Green

Orange

Green

Orange

With the target in place, turn the trimmer to
"Max." With the receiver in place, move the
transmitter up/down and right/left. Set the
transmitter at the midpoint of the range where
the green LED is lit. Secure the transmitter and
adjust the receiver position in the same way.

Turn the trimmer counterclockwise from Max.
until the green LED turns off. Assume the
position as Point A.

Optimal
position

Set the trimmer midway between point A and
Max. Confirm sensor operation.

A

A

1

2

3

Proce-
dure

Operation

Trimmer

Indicators

Adjustment

Green

Orange

Green

Orange

Green

Orange

Optimal
position

Multi-reflective type

With no target, turn the trimmer clockwise until
the orange indicator illuminates (turns off) and
assume the position as Point A. If the LED
does not illuminate (turn off) even with the
trimmer at Max., use Max. as Point A.

With the target in place, turn the trimmer
counterclockwise from Point A until the green
LED turns off. Assume the position as Point B.

Set the trimmer midway between points A and
B. Confirm sensor operation.

B

A

A

A

1

2

3

PZ-M (Trimmer type)

• DARK-ON mode (When LIGHT-ON mode is selected, refer to the

description in parentheses.)

• LIGHT-ON mode (When DARK-ON mode is selected, refer to the

description in parentheses.)

* The adjustment for the retroreflective type is the same as for the thrubeam type.

Press the and

buttons simul-

taneously and
release them.

Change the
display as shown
on the right

Display

ON/OFF
display

ON

OFF

Press the and

buttons simul-

taneously for
three seconds
or more.

Lock the operation
buttons to avoid
the preset value
from being
accidentally
changed.

flashes and then

the normal display
appears.

Press the and
buttons simul-
taneously for
three seconds
or more.

Unlock the
operation buttons
to allow the preset
value to be
changed.

flashes and then

the normal display
appears.

UL Certificate

This product is an UL/C-UL Listed product.
• UL File

No. E301717

• Category

NRKH,NRKH7

• Enclosure Type 1 (Based on UL50)

Be sure to consider the following specifications when using this product as an UL/C-UL
Listed Product.
• Use the power supply with Class 2 output defined in NFPA70 (NEC: National Electrical

Code).

• Power supply/ Control input/ Control output circuits shall be connected to a single Class 2

source only.

• Use with the over current protection device which is rated 24V or more and not more than

2A.

Precautions on Regulations and Standards

Advertising