KEYENCE LR-ZB250AN/AP User Manual

Self-contained cmos laser sensor, Instruction manual, Safety information for lr-zb series

Advertising
background image

1

LR-ZB250AN/P_IM_E

Self-contained
CMOS Laser Sensor

LR-ZB250AN/ZB250AP

Instruction Manual

Read this manual before using the product in order to achieve maximum performance.

Keep this manual in a safe place after reading it so that it can be used at any time.

The following symbols alert you to important messages.

Be sure to read these messages carefully.

* The laser classification for FDA (CDRH) is implemented based on IEC60825-1 in

accordance with the requirements of Laser Notice No.50.

„

Certification and
Identification Label

• When using this product in the

U.S. affix the Certification and

Identification Label included in

the package of this product as

shown on the right.

(Affix this label in a location that is not splashed with oils or chemicals.)

„

UL Certification

This product is an UL/C-UL Listed product.

• UL File No.: E301717, Category: NRKH/NRKH7, Enclosure Type 1 ( UL50 )

Be sure to consider the following specifications when using this product as a UL/CUL

Listed Product.

• Use a power supply with Class 2 output defined in NFPA70 (NEC: National Electrical

Code).

• Power supply, external input and control output circuits shall be connected to a single

Class 2 source only.

„

CE Marking

KEYENCE Corporation has confirmed that this product complies with the essential

requirements of the applicable EC Directive, based on the following specifications.

Be sure to consider the following specifications when using this product in a member state

of European Union.

z

EMC Directive (2004/108/EC)

• Applicable standard

EMI: 60947-5-2, Class A, EMS: 60947-5-2

These specifications do not give any guarantee that the end-product with this product

incorporated complies with the essential requirements of EMC Directive. The

manufacturer of the end-product is solely responsible for the compliance on the end-

product itself according to EMC Directive.

*1 Display reading used as a guide for the detecting distance. When the setting value is

tuned, the readout shifts. When the value exceeds “-99”, “-FF” is displayed.

*2 The display resolution is “1” in “I-DATUM mode”.

*3 The laser classification for FDA (CDRH) is implemented based on IEC60825-1 in

accordance with the requirements of Laser Notice No.50.

*4 When the response time is 10 ms

LR-ZB250AN

LR-ZB250AP

It indicates a hazardous situation which, if not avoided, could result in

death or serious injury.

It indicates a situation which, if not avoided, could result in product

damage as well as property damage.

Safety Information for LR-ZB Series

• This product is only intended to detect object(s). Do not use this

product for the purpose to protect a human body or part of a human

body.

• This product is not intended for use as an explosion-proof product.

Do not use this product in a hazardous location and/or potentially

explosive atmosphere.

• This product uses DC power. The product may explode or burn if an

AC voltage is applied.

• Do not wire the cable along with power lines or high-tension lines,

as the sensor may malfunction or be damaged due to noise.

• When using a commercially available switching regulator, ground

the frame ground terminal and ground terminal.

• Do not disassemble this product. Laser emission from this product

is not automatically stopped when it is disassembled.

• Use with an over current protection device which is rated 30 V or

more and not more than 1 A.

Safety Precautions on Laser Product

• This product employs a semiconductor laser for the light source.

• Use of controls or adjustments or performance of procedures other

than those specified herein may result in hazardous radiation

exposure.

Follow the instructions mentioned in this manual. Otherwise, injury to

the human body (eyes and skin) may result.

• Laser emission from this product is not automatically stopped

when it is disassembled. Do not disassemble this product.

• Do not stare into the beam.

Wavelength/Output

660 nm/145 μW

FDA(CDRH) Part1040.10

*

Class 1 laser product

IEC 60825-1

Class 1 laser product

Consignes de sécurité relatives au Laser

L’utilisation des commandes ou réglages ou l’exécution des

procédures autres que celles spécifiées dans les présentes exigences

peuvent être la cause d’une exposition à un rayonnement dangereux.

Precautions on Regulations and Standards

WARNING

NOTICE

WARNING

NOTICE

WARNING

Certification and
Identification Label

AVERTISSEMENT

Specifications

Type

Distance setting

Appearance

Rectangular

NPN

LR-ZB250AN

PNP

LR-ZB250AP

Detectable distance

35 to 250 mm (215 to 0)

*1

Standard detection deviation

35 to 180 mm : 9 mm

180 to 250 mm : 25 mm

Display resolution

*2

1 to 3 (1 to 3 mm)

Spot diameter

2.4 X 1.2 mm at 250 mm

Response time

1.5 ms / 10 ms / 50 ms selectable

Connection

2 m cable

Type

Red laser (660 nm)

Laser class

Class 1 laser product

(IEC60825-1, FDA (CDRH) Part1040.10

*3

)

Indicator

3-digit 7-segment display (red),

output indicator (yellow),

DATUM indicator (orange), 1 spot indicator (green)

Timer

OFF/ON delay/OFF delay/One-shot

Power voltage

10 to 30 VDC, including 10% ripple (P-P), Class 2 or LPS

Power consumption

450 mW or less (18 mA or less at 24 V, 34 mA or less at 12V)

Control output

LR-ZB250AN: NPN Open collector

LR-ZB250AP: PNP Open collector

Applied voltage 30 VDC or less,

Control current 100 mA or less,

Residual voltage 1.2 V or less at 10 mA or less,

2 V or less at 10 to 100 mA

Protection circuit

Protection against reverse power connection, output overcurrent,

output surge, reverse output connection

Output operation

Light-ON / Dark-ON selectable

External input

Short-circuit current NPN: 1 mA or less/PNP: 2 mA or less

For input time, refer to the time chart. (Instruction manual P3)

Enclosure rating

IP68 (IEC60529)/IP69K (DIN40050-9)/

4X, 6P, 13 (NEMA250)

Ambient light

*4

Incandescent lamp: 2000 lx or less

Sunlight: 4000 lx or less

Ambient temperature

-10 to +50°C (No freezing)

Storage temperature

-25 to +75°C

Ambient humidity

35 to 85%RH (No condensation)

Shock resistance

1000 m/s

2

in X, Y, Z axis directions respectively 6 times

Vibration resistance

10 to 55 Hz Double amplitude 1.5 mm in the X, Y, Z

axis directions respectively, 2 hours

Insulating resistance

20 M

Ω or more (500 VDC)

Withstand voltage

1000 VAC 50/60 Hz 1 min

Material

Case: SUS316L, Display: PES,

Lens cover: PMMA with scratch-resistant coating,

Packing/Connector ring: FKM

Weight

Approx. 110 g (Including cable)

I/O Circuit Diagram

Model

Light sour

ce

Fu

nct

ion

Spe

cific

ations

E

nvi

ronm

en

ta

l r

esi

st

anc

e

3 VDC

PLC, etc.

Sensor main circuit

Load

Ov

ercurrent

protection circuit

10 to 30 VDC

0 V

Brown

Blue

White

Black

Sensor main circuit

Load

Ov

ercurrent

protection circuit

10 to 30 VDC

0 V

Brown

Blue

White

Black

96M12305

Advertising