Basic operation, Part names and functions, Package contents – KEYENCE LR-ZB250AN/AP User Manual

Page 2: Installation, Wiring, Output configuration (l.on ↔ d.on), Sensitivity adjustment

Advertising
background image

2

LR-ZB250AN/P_IM_E

„

Installation

„

Output configuration (L.ON D.ON)

„

Sensitivity adjustment

Basic Operation

„

Part names and functions

„

Package contents

• DOWN
• MODE

Calibration

DTM: This lights up when datum

calibration is performed.

1 spot: This turns off when no light enters

or multiple reflections occurs.

• UP
• L.ON/D.ON

• Certification and

Identification Label

• Sensor

• Instruction Manual

OK

NG

Tightening Torque: 0.6 Nm or less

25.4 mm

M3

Direction of installation

„

Wiring

Brown: 10 to 30 V
White: IN
Blue: 0 V
Black: OUT

L.ON

1

(Detection
Status)

> 3s

2

D.ON

3s

(Detection Status)



.QP



&QP

Output at the time
of D.ON

Output at the time
of L.ON

ON
OFF

ON
OFF

Operation

z

Basic setting (high accuracy)

(2-point calibration, background

suppression - BGS)

z

When an object other than the

background is to be detected

(Datum calibration, foreground

suppression - FGS)

z

When an object located nearer

than the background is to be

detected (Maximum sensitivity

calibration, background

suppression - BGS)

z

Moving target calibration

(Full auto calibration,

background suppression - BGS)

z

Manual adjustment

Press again
< 1s

1

2

Setting value

or NG

OK





When the difference
is too small

Press briefly
< 1s

Completed

DTM

Setting value -A

1

2

Setting value A

or NG

OK





When the 1 spot
indicator light is off

Press and
hold
> 3s

Press briefly
< 1s

Release the button when [

5'6] flashes

Completed

1

OK



Press and
hold
> 3s

Setting value

Completed

Release the button when [

5'6] flashes

Let the detected object pass
with the button pressed until
[

5'6] flashes.

1

Press and
hold
> 3s

Setting
value

OK



* This function cannot be used when
the background is not within
the detecting area.

Completed

Adjust
sensitivity

1

(Run Mode)

2

-99 to 999

(Run Mode)

Press briefly
< 1s

3s







Completed

Advertising