1

RGB Digital Fiberoptic Sensors

CZ Series

Instruction Manual

SAFETY PRECAUTIONS

This manual describes the instructions, operating procedures and
precautions for using the CZ Series.
Before beginning operation, please read this manual carefully to get the
most from your CZ Series.
Keep this manual handy for future reference.

• The CZ Series is intended for the detection of target objects. Do

not use the CZ Series in a safety circuit to protect the human
body.

• The CZ Series does not have an explosion-proof structure. Do

not use it in a location where any flammable gases, liquid or
powder exist.

ACCESSORIES

WARNING

SPECIFICATIONS

Model
Light source
Response time

Indicators

Error indication

Calibration method
Tolerance value
adjustment
Differentiation mode
Timer function

Output mode
selection

External synchro-
nization input
External calibration
input
Registered color
selection

Control output

Protection circuit

Power supply
Current
consumption

Ambient light

Ambient
temperature

1.

Relative humidity

Vibration

Shock
Housing material
Weight (including
2 m cable)

CZ-V1

Red LED, Green LED, Blue LED

300

µs/1 ms (switch selectable)

Output: Red LED, Calibration: Orange LED,

External synchronization input: Green LED,

Matching rate/received light intensity: LCD (Red/Green)

Excess light intensity, insufficient light intensity,

insufficient color difference

1-point/2-point calibration (switch selectable)

Numerical value setting on digital display

C mode/C + I mode/I mode (switch selectable)

Timer OFF/OFF-delay timer (40 ms) (switch selectable)

Match output: Turns on when target color

matches registered color.

Mismatch output: Turns on when target color is different

from registered color. (switch selectable)

Response speed: 500

µs max.

Input response time: 20 ms min.

8-bank selection (By external input or key operation),

Input response time: 20 ms min.

NPN open-collector: 40 VDC max. (100 mA max.),

Residual voltage: 1.0 V max.

Reverse-polarity protection (power supply),

overcurrent protection (output), surge protection (output)

12 to 24 VDC

±10%, Ripple (P-P): 10% max.

75 mA max.

Incandescent lamp: 5,000 lux max.,

Sunlight: 10,000 lux max.

–10 to +55

°C (14 to 131°F), No freezing

35 to 85%, No condensation

10 to 55 Hz, 1.5 mm double amplitude in X, Y, and Z

directions, 2 hours respectively

500 m/s

2

in X, Y, and Z directions, 3 times respectively

Polycarbonate

Approx. 115 g

1. When several units are connected, the acceptable ambient temperature varies

depending on the conditions given below. To connect several units, be sure to
mount them to a DIN rail (metallic plate). Ensure that the output current is 20
mA max.
• When 3 to 10 units are connected: -10 to +50

°C (14 to 122°F)

• When 11 to 16 units are connected: -10 to +45

°C (14 to 113°F)

Amplifier

Fiber unit

Detection method

Model

Type

Detection range

Smallest spot diameter

Minimum bend radius

Enclosure rating

Ambient temperature

Relative humidity

Fiber length

Housing material

Weight

CZ-40

Long detecting distance

70

±20 mm

6 mm dia.

R25 mm

Reflective

IP67

–40 to +70

°C (–40 to 158°F), No freezing

35 to 85%, No condensation

2 m (free-cut)

Polyarylate

Approx. 27 g

CZ-41

Small beam spot

16

±4 mm

1 mm dia.

R15 mm

Type

Model

Detection range

Smallest spot diameter

Minimum bend radius

Enclosure rating

Ambient temperature

Relative humidity

Fiber length

Housing material

Weight

Adjustable small beam spot

CZ-10

10 to 30 mm

0.9 to 3.5 mm dia.

Reflective

R25 mm

IP40

–40 to +70

°C (–40 to 158°F), No freezing

35 to 85%, No condensation

Lens housing: Aluminum, Fiber case: Stainless steel

Adjustable small beam spot, sideview

CZ-11

3 to 15 mm

0.9 to 1.5 mm dia.

2 m (free-cut)

1 m (free-cut)

Approx. 5 g

Approx. 13 g

Instruction manual (This manual): 1

Mounting bracket: 1

Plastic screw driver: 1

96M0744