KEYENCE EM Series User Manual

Em series, Instruction manual, Proximity sensors with in-cable amplifiers

Advertising
background image

Copyright (c) 2008 KEYENCE CORPORATION. All rights reserved.
0202E 1112-2a 96M0202
Printed in Japan

Proximity sensors
with in-cable amplifiers

EM series

Instruction Manual

96M0202

KEYENCE, at its sole option, will refund, repair or replace at no charge any
defective Products within 1 year from the date of shipment. Unless stated
otherwise herein, the Products should not be used internally in humans, for
human transportation, as safety devices or fail-safe systems.

EXCEPT FOR

THE FOREGOING, ALL EXPRESS, IMPLIED AND STATUTORY

WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY,

FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT OF

PROPRIETARY RIGHTS, ARE EXPRESSLY DISCLAIMED. KEYENCE

SHALL NOT BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL,

CONSEQUENTIAL OR OTHER DAMAGES, EVEN IF DAMAGES RESULT

FROM THE USE OF THE PRODUCTS IN ACCORDANCE WITH ANY

SUGGESTIONS OR INFORMATION PROVIDED BY KEYENCE. In some
jurisdictions, some of the foregoing warranty disclaimers or damage limitations
may not apply.

E 1101-3

Output circuit

Hints on correct use

NPN type

Brown

Black

(control output)

Blue

Load

DC10.8 to 30V

0V

PNP type

DC10.8 to 30V

0V

Brown

Black

(control output)

Blue

Load

Pro

ximity

sensors

main circuit

Pro

ximity

sensors

main circuit

Do not use this product for
the purpose of protecting the
human body.

Warning

Mounting cylindrical type

● Attach the mounting screw to the sensor

at minimum of 5mm away from the tip
of the sensor.
Be sure to keep the tightening torque
less than 0.4Nm when mounting.

M3 screw

5mm min

Mounting thread type

When mounting thread type sensor head,
tightening torque should be less than
specified below.

Model

EM-005
EM-010
EM-014

Torque

1.5Nm max.

10Nm max.
20Nm max.

Influence of surrounding metallic
objects

● To flush mount the sensor that is

embedded in iron, provide enough
distance between the sensor and
surrounding iron as shown by the
following figure and table, because the
detecting distance is reduced by 10%.

L

B

A

Model
L(

mm

)

A(

mm

)

B(

mm

)

EM-030

4
6
5

EM-038

4

7.6

5

EM-030

4

10

5

EM-030

4

10.8

5

EM-030

5

16

8

EM-030

5

20

8

EM-030

5

28

8

Note: Consult Keyence regarding nonferrous materials.

Mutual interference

When installing a number of proximity
sensors of the same model either face-to-
face or side-by-side, provide the minimum
distance given in the table between each
sensor.
Note :

Two types with different frequencies available.
(A) or (B) is written after each type name.

EM-030
EM-038
EM-005
EM-054
EM-080
EM-010
EM-014

12(1)
15(1)
12(1.5)
20(1.5)
24(2.5)
20(2.5)
40(4.5)

11

(contact installation)

12

(contact installation)

13

(contact installation)

18

(contact installation)

23

(contact installation)

25

(contact installation)

34

(contact installation)

Model

Distance

Face-to-face

installation

(

)

Side-by-side

installation

(

)

Installing amplifier unit

A mounting bracket is
supplied as a standard
accessory. Use it to secure
the amplifier unit.
Do not use setscrews to

secure the amplifier unit.

Align the operation indicator of the
amplifier so that it positions at the center of
the mounting bracket hole as shown
below.

(4

mm

dia)

Operation indicator

mounting bracket hole

Wiring

● To extend the cord, use an extension

cord with a conductor cross-sectional
area of 0.3mm

2

. Limit the length of the

extension to within 50m. Note that the
coaxial cord must not be extended or
cut.

● Ensure that the sensor cord is kept

away from power lines and high-
tension lines; otherwise, noise may
cause the sensor to malfunction.

The values enclosed in brackets are

when a different frequency type is used.

3

EM-030

0.6mm±15%

Approx. 36g

3.8

EM-038

0.8mm±15%

5×5mm

Approx. 38g

M5

EM-005

1.0mm±15%

5.4

EM-054

1.2mm±10%

6×6mm

8

EM-080

2.0mm±10%

Approx. 42g

M10

EM-010

2.0mm±10%

Approx. 50g

M14

EM-014

4.0mm±10%

15×15mm

Approx. 60g

Rating

Environmental durability

10×10mm

Approx. 40g

Type

Shape

Model

Detecting distance

Target

Standard target
[iron, t=(1

mm

)]

Hysteresis

Response frequency

Output mode

Temperature drift

Control output

Supply voltage

Current
consumption

Degree of
protection

Ambient
operating
temperature

Relative
humidity

Head case material

Weight(nuts and
2 meter-long
cable included)

Ferrous metals (See catalog for nonferrous metals)

10% max. of detecting distance

1.2kHz

N.O.

±10% of detecting distance at 23˚C (73˚F) [-10 to +70˚C (-13 to +158˚F)]

NPN open-collector 200mA max. (40V max.) Residual voltage : 1V max.

PNP open-collector 200mA max. (30V max.) Residual voltage : 1V max. 1

10.8 to 30VDC, Ripple(P-P) : 10%max. 2

12mA max. (20mA max 3)

IP67 (Use oilresistant cord)

-25 to +80˚C (-1 to +176˚F), No freezing

35 to 95%, No condensation

Stainless steel

Chromium plates brass

Shielded

Cylindrical Cylindrical

Thread

type

Thread type

1 PNP output types are different models from NPN output types and specified by letter P at the end of the model
numbers.(Ex : EM-030P)
2 Use a power range between 10.8 and 30V if ripple occurs.
3 The figures in ( ) are for PNP output type.

Specifications

WARRANTIES AND DISCLAIMERS

Advertising