4

Specifications are subject to change without notice.

KEYENCE CORPORATION

1-3-14, Higashi-Nakajima, Higashi-Yodogawa-ku,
Osaka, 533-8555, Japan
PHONE: +81-6-6379-2211

Copyright (c) 2010 KEYENCE CORPORATION. All rights reserved.

11224E 1070-1 96M11224
Printed in Japan

A7WW1-MAN-0069

9. Key Lock

The key lock function disables the operation of all keys.

Indicates that the
keys are locked.

Press the manual button for
three seconds while pressing
the mode button.

• Take the same step to unlock the keys.

10. Mode Settings before Shipping (Initialization)

The following factory settings are made before shipping.

EASY

FINE

OFF

Light-ON

Access mode

Power mode

Timer function

Output selection

* Returning to factory settings: Press the

button for a minimum of

five seconds while pressing the button.

11. Hints On Correct Use

• To extend the cable length, use a cable with at least a 0.3 mm

2

cross-

section area. Limit the length of cable extension to no more than 100 m.
(To connect several units, contact Keyence for further information.)

• Do not wire the amplifier line along with power lines or high-tension

lines, or otherwise the sensor may malfunction or receive damage due
to noise.

• When using a commercially available switching regulator, ground the

frame ground terminal and ground terminal.

• Do not use the FS series outdoors, or in a place where extraneous light

can enter the light receiving surface directly.

• Due to the individual dispersion of characteristics and the difference in

fiber unit model, the maximum sensing distance or displayed value of
all the units are not the same.

• If the sensor is used in S-APC mode for a long time, the LED indicators

will be imposed with a heavy load. In that case, the sensor will be auto-
matically set to ACC mode where the current consumption of the sen-
sor for light emission will be constant, and “END APC” will be displayed.
The sensor can be continuously used in this case. Replace the sensor,
however, if highly precise detection is required.

12. Specifications

Model
Light source

Response time *1

Display shift function

Timer function

Control output

Supply voltage
Current consumption

Ambient
illumination
Ambient
temperature
Relative humidity

Vibration

Shock resistance

Housing material
Size
Weight

FS-V22

FS-V22G FS-V22R(P) FS-V20R

FS-V22X

Red LED Greed LED 4-element red LED 4-element red LED Infrared (950 nm)

250µs (FINE)/500µs (TURBO)/1ms (SUPER TURBO)/
4ms (ULTRA TURBO)/500µs (HIGH RESOLUTION)/
50µs (HIGH SPEED)
Max. ±1999 (variable)
Timer OFF, OFF-delay timer, ON-delay timer, and one-shot timer
1 to 500 ms
NPN open collector output at 40 V (or PNP open collector output
at 30 V) with 20 mA max. and a residual voltage of 1 V max.
DC12-24V ±10% with a maximum ripple (peak to peak) of 10%, Class 2

Incandescent lamp: 20,000 lux max.
Sunlight: 30,000 lux max.

-10°C to 55°C (No freezing)*2

35% to 85% RH (No condensation)
10 to 55 Hz, 1.5-mm double amplitude,
each in X, Y, and Z directions for two hours
500 m/s

2

Three times each in X, Y, and Z directions

Unit and cover are both polycarbonate made
W 9 mm x L70 mm x H 30 mm
Approximately 45 g (including 2-m Cable)

Rating

Environment resistance

Mode

S-APC
mode OFF
580 mW
480 mW
430 mW
650 mW
530 mW
480 mW

S-APC mode turned ON or when
the HIGH SPEED mode is selected.

720 mW
600 mW
550 mW
720 mW
600 mW
550 mW

Normal
ECO half
ECO all
Normal
ECO half
ECO all

Model

Other than
R model

R model

*1. The FS-V20R has a response time between 210µs and 4.7 ms, de-

pending on the number of Units connected.

*2. Ambient operating temperature with amplifier expansion

1 to 2 units: -10°C to 55°C
3 to 10 units: -10°C to 50°C
11 to 16 units: -10°C to 45°C

13. List of Digital Display Items

Preset value/Current value display

Output selection (Dark ON)

Output selection (Light-ON)

Access mode selection (EASY)

Access mode selection (FULL)

Excess gain display

LED bar display

Hold display

Power mode selection (FINE)

Power mode selection (TURBO)

Power mode selection (SUPER TURBO)

Power mode selection (ULTRA TURBO)

Power mode selection (HIGH SPEED)

Power mode selection (HIGH RESOLUTION)

Timer function setting (Timer OFF)

Timer function setting (OFF-delay timer)

Timer function setting (ON-delay timer)

Timer function setting (One-shot timer)

S-APC mode setting (S-APC OFF)

S-APC mode setting (S-APC ON)

Edge detection mode (OFF)

Edge detection mode (Rising edge)

Edge detection mode (Falling edge)

ECO mode setting (ECO mode OFF)

ECO mode setting (ECO half)

ECO mode setting (ECO all)

Shift function setting (Shift OFF)

Shift function setting (Shift ON)

Key lock setting

Key unlock

Forecast maintenance warning (END APC)

KEYENCE products are strictly factory-inspected. However, in the event of a failure, contact
your nearest KEYENCE office with details of the failure.

1. WARRANTY PERIOD

The warranty period shall be for one year from the date that the product has been
delivered to the location specified by the purchaser.

2. WARRANTY SCOPE

(1) If a failure attributable to KEYENCE occurs within the abovementioned warranty period,

we will repair the product, free of charge. However, the following cases shall be
excluded from the warranty scope.
• Any failure resulting from improper conditions, improper environments, improper

handling, or improper usage other than described in the instruction manual, the
user’s manual, or the specifications specifically arranged between the purchaser and
KEYENCE.

• Any failure resulting from factors other than a defect of our product, such as the

purchaser’s equipment or the design of the purchaser’s software.

• Any failure resulting from modifications or repairs carried out by any person other

than KEYENCE staff.

• Any failure that can certainly be prevented when the expendable part(s) is

maintained or replaced correctly as described in the instruction manual, the user’s
manual, etc.

• Any failure caused by a factor that cannot be foreseen at a scientific/technical level

at the time when the product has been shipped from KEYENCE.

• Any disaster such as fire, earthquake, and flood, or any other external factor, such as

abnormal voltage, for which we are not liable.

(2) The warranty scope is limited to the extent set forth in item (1), and KEYENCE assumes

no liability for any purchaser’s secondary damage (damage of equipment, loss of
opportunities, loss of profits, etc.) or any other damage resulting from a failure of our
product.

3. PRODUCT APPLICABILITY

KEYENCE products are designed and manufactured as general-purpose products for
general industries.
Therefore, our products are not intended for the applications below and are not
applicable to them. If, however, the purchaser consults with us in advance regarding
the employment of our product, understands the specifications, ratings, and
performance of the product on their own responsibility, and takes necessary safety
measures, the product may be applied. In this case, the warranty scope shall be the
same as above.
• Facilities where the product may greatly affect human life or property, such as

nuclear power plants, aviation, railroads, ships, motor vehicles, or medical
equipment

• Public utilities such as electricity, gas, or water services
• Usage outdoors, under similar conditions or in similar environments