Counting mode – A&D Weighing SE-150KAL User Manual

Page 16

Advertising
background image

14

7. COUNTING MODE

Determines a unit weight (the weight of one piece) from the known pieces of samples,
and calculates how many pieces are on the weighing pan using the unit weight.
The unit weight is maintained even if the power is turned OFF.


1. Press the UNITS switch to select “pcs”.

(“pcs” = pieces)



2. Press and hold the UNITS switch to

enter the sample unit weight storing mode.
The numerical value on the left indicates
the number of samples.



3. To change the number of samples, press the

PRINT switch. It may be set to 5, l0, 20, 50

or l00.



4. If necessary, place a container on the

weighing pan, and press the TARE

1

switch. Confirm that the right side of the
number of samples shows zero.





5. Place the correct number of samples on

the weighing pan or in the container.





6. Confirm that the STABLE indicator is turned on.

Press the UNITS switch to calculate and
store the unit weight. Remove the samples. The
scale is set to count objects with this unit weight.


‰

The total weight of samples should be more than

shown below, regardless of the number of samples.

Weighing capacity of 30 kg: 0.05 kg
Weighing capacity of 60 kg: 0.1 kg
Weighing capacity of 150 kg: 0.2 kg

If not, the display shows “

lo ut

” and returns to the

display of step 5. Increase the number of samples
(step 3) and try again.


7. Place the objects to be counted on the weighing pan.

ZERO

ZERO

ZERO

STABLE

Confirm

zero

Number of

samples

Samples

Weighing

pan

Container

Press

Press and hold

Press

Press

Press

Advertising