A&D Weighing AD-4407 User Manual

Page 29

Advertising
background image

AD-4407 Weighing Indicator

Page

27

Data Output *: Initial

settings.

Item

Parameter

Description

** 0

No data output

1

Analog output

Set f31, 32, 33

2

Serial output

f30
Data output

3

Serial output (Zero suppressing)

RS-232C,
RS-422/485

Analog Output *:

Initial

settings.

Item

Parameter

Description

* 0

Display data

1

Gross data

f31
Output data

2

Net data

f32
Weight value at 4mA output

-999999 to 999999 (Initial setting is 0)

f33
Weight value at 20mA output

-999999 to 999999 (Initial setting is
10000)

Polarity is
changed by
pressing the +/-
key.

Serial Data Format

Item

Parameter

Description

x 0

Terminator

x 1

Device ID (selected at f06)

x 2

Code number

x 3

Data number *

x 4

Result of comparison

x 5

(Reserved)

x 6

(Reserved)

x 7

Accumulated value

x 8

Accumulation count

x 9

Stable / Over

x a

Displayed weight

x b

Gross weight

x C

Net weight

x d

Tare weight

x e

Weight type (

G /N / T

, refer to Cf06)

f34

[Type3]

Serial data format 1

Initial value
19, 2e, 3a 4f e50



f35

[Type3]

Serial data format 2

Initial value
17 2f e30

x f

Weight unit (cf. Cf07)

ZERO

key :

Order of output
(1 to 999)
“Exxx” indicates
the end of data
to output

NET/GROSS

key:

Expand or
shorten output
data length

0

-

9

,

A

-

F

key:

output data

1 Comma of the parameter display indicates that the comma (f46 0, semi-colon for

f46 1) is output after the data. To turn this mark on and off, press the

9

key while

pressing

NET/GROSS

key.

Output of initial settings of f34(19, 2e, 3a 4f e50) is like “ST,GR,+12345.6kg”.

2 The data number *(parameter 3) increments automatically with each serial data

output from 1 to 99999 (the next after 99999 is 1). The starting number can be set

by the keys.

Press the

CODE(1)

key while pressing the

PRINT

key at weight display, the display

changes to data r then r xxx. “xxx” is the next data number. Using the

0

-

9

keys to

enter the number and pressing the

ENTER

key to store the number and return to

weight display.

6.2.

F-Functions

Advertising