A&D Weighing AD-4407 User Manual

Page 59

Advertising
background image

AD-4407 Weighing Indicator

Page

57

15.

15.

15.

15. Relay Output & Control Input (OP

Relay Output & Control Input (OP

Relay Output & Control Input (OP

Relay Output & Control Input (OP-

-

-

-05)

05)

05)

05)

Replacing the RS-232C interface with this option, 3-relay outputs and 3-control inputs

can be used with the RS-232C interface of this option.

RS-232C functions are the same as the RS-232C interface described in “13. RS-232C

Interface”.

The solid state relays output the result of comparison.

The control inputs can control the indicator from an external terminal just like the front

panel key operations.

Set the external control function at f13 - f15 of the F-Functions.

When connecting each function pin to the common pin, the indicator makes the action.

Keep a signal width of more than 100ms for the On-time and Off-time.

ON(Make)

OFF(Break)

Pin co

Pin co

Pin co

Pin connections and Circuits

nnections and Circuits

nnections and Circuits

nnections and Circuits

Function Pin No. Signal name

Direction

Description

1 TXD

Output Transmit

data

2 RXD

Input Received

data

3

DSR

Output

Data set ready

RS-232C

4 SG

-

Signal

ground

5

HI

Output

Relay output HI

6

OK

Output

Relay output OK

7

LO

Output

Relay output LO

Relay

output

8

COM(out)

-

Relay output common

9

EXT1

Input

Control input 1 (f13)

10

EXT2

Input

Control input 2 (f14)

11

EXT3

Input

Control input 3 (f15)

Control

input

12

COM(in)

-

Control input common

FG

13

FG

-

Frame ground (case)

15. Relay Output & Control Input (OP-05)

6:& 4:& &54 5) *+ 1- .1 %1/Q ':6

Relay output

RS-232C

Ʈ



















':6 ':6 %1/K ()









Control input

Case

K



Relay specifications

Maximum voltage
DC50V
Maximum current
DC100mA
Maximum resistance

8

9

More than 100ms

More than 100ms

Advertising