AD-4407 Weighing Indicator

Output of Accumulation Data

Accumulated data can be output to the serial interface.

Output by manual or automatic, and output data format is selected at f41 of the

F-function setting.

F41

Parameter

Manual/Automatic Format

0

No output

* 1

Manual

2

Automatic

Fixed format

3

Manual

4

Automatic

Format 1(selected at f34)

5

Manual

Accumulated data
output at
accumulated data
display

6

Automatic

Format 2(selected at f35)

Step 1 Press the

TOTAL

key to display

total

and the accumulated data.

Step 2 If automatic output is set, the data is output once at that timing.

Step 3 If manual output, by pressing the

PRINT

key while the accumulated data is displayed,

the data is output.

Fixed data format :

9.

9.

9.

9. Code

Memory

Code Memory

Code Memory

Code Memory

This indicator has four code memories (1 through 4). Each code memory stores a set

of setpoints, preset tare and the unit weight for piece counting.

The data is stored in non-volatile memory, and is not lost even if the AC power supply

is disconnected or cut off.

Memory number 0 is a temporary memory and the data is lost when the AC power

supply is disconnected or cut off.

The active code memory number can be changed by key switch, external control

input, or a command via the serial interface.

The data set can be copied from one code memory to another code memory.

8. Accumulation