A&D Weighing AD-4407 User Manual

Page 55

Advertising
background image

AD-4407 Weighing Indicator

Page

53

13.4.

13.4.

13.4.

13.4. UFC Command

UFC Command

UFC Command

UFC Command

UFC(Universal Flexi Coms) function enables editing the serial data output format

freely using the serial interface command.

For customizing the print out of the printer or efficient data collecting.

Output data is not only the indicator’s data/status but also characters at will.

It can output the control code* of the printer. (* depends on the individual printer)

There are 2 set of memories for storing the parameters.

UFC Command Parameter

UFC Command Parameter

UFC Command Parameter

UFC Command Parameter

UFC commands such as SF1 have many parameters.

One command line can has a multiple number of parameters. Parameters are

stored in memory in order.

Multiple UFC commands are possible. The parameters are stored next to the last

parameter stored by the last UFC command.

Clear all of the data first, if storing a new set of parameters. The parameters in

the stored data can not be changed partially.

The various types of parameters and their descriptions are shown below.

data

Weight, result of comparison etc.

$CL

Clear previous settings. UFC command parameters can not be

changed partially.

$WT Displayed

data

$GR GRoss

data

$NT NeT

data

$TR TaRe

data

$HD

HeaDer of Gross/Net/Tare or Preset tare. Refer to CF06.

$UT Weight

UniT

$ST STable/Unstable

$CP

Result of ComParison

$ID

ID number specified at F06

$DN

Data Number increments with each output automatically

$CD

CoDe memory number

$AN Accumulation

count

$TL TotaL

weight

$CM CoMma

$CR

CR code (0Dh)

$LF

LF code (0Ah)

$DE

DElete the last parameter

$DL

Inserting DeLay time (0.1 second step)

Example: DL10: 1.0 second delay

13.4. UFC Command Parameter

Advertising