B-21

Cisco AS5400XM Universal Gateway Chassis Installation Guide

OL-6418-02

Appendix B Replacing the Power Supply

Configuring the Power Supply Alarm

Verify Power Supply Alarm Configuration

To verify the status of the power supply alarm configuration, enter the show facility-alarm command:

5400# show facility-alarm

Device State

------ -----

GigabitEthernet0/0 UP

Modem Card 4 UP

Facility Alarm is ON

Note

For information on connecting alarm devices to the alarm port on the Cisco AS5400XM
universal gateway, see the

“Connecting to the Alarm Port” section on page 3-11

.

Step

Command

Purpose

Step 1

Router> enable

Password: password

Router#

Enters enable mode. Enter the password.

You have entered enable mode when the prompt changes to

Router#

.

Step 2

Router# configure terminal

Enters global configuration mode.

Step 3

Router(config)# facility-alarm detect rps

Turns on an alarm when a redundant power supply failure is
detected. Any of the following failures will turn on the alarm:

Input power voltage failure

Output power voltage failure

Overvoltage condition

Multiple failures