Power switch, Indicator light - “mix low, Mix refrigeration button – Carrier 336 User Manual

Page 14: Standby, Wash, Auto

Advertising
background image

10

Models 336, 338 & 339

Important: To the Operator

Power Switch

When placed in the “ON” position, the power switch

allows SOFTECHR control panel operation.

Indicator Light - “Mix Low”

Located on the front of the machine is a mix level

indicating light. When the light is flashing, it indicates

that the mix hopper has a low supply of mix and should

be refilled as soon as possible. Always maintain at

least 3” (76 mm) of mix in the hopper. If you neglect to

add mix, a freeze-up may occur. This will cause

eventual damage to the beater, blades, drive shaft,

and freezer door.

Mix Refrigeration Button

When the mix refrigeration button is pressed, the light

comes on indicating the mix hopper refrigeration

system is operating. The mix refrigeration is controlled

by the left side of the freezer as viewed from the

operator end. The mix refrigeration function cannot be

cancelled unless the “AUTO” or “STANDBY” modes

are cancelled first.

“Standby”

The Separate Hopper Refrigeration System (SHR)

and the Cylinder Temperature Retention System

(CTR) are standard features. The SHR feature

incorporates the use of a separate small refrigeration

system to maintain the mix in the hopper below

40_(4.4_C) to assure bacteria control. The CTR

feature works with the SHR to maintain a good quality

product. During long “No Sale” periods, it is necessary

to warm the product in the freezing cylinder to

approximately 35_F to 40_F (1.7_C to 4.4_C) to

prevent overbeating and product breakdown.

To activate the SHR and CTR features, press the

“STANDBY” button. Remove the air orifice and place

the air tube (end without the hole) into the mix inlet

hole.

When the “STANDBY” button is pressed, the light

comes on, indicating the CTR (Cylinder Temperature

Retention System) feature has been activated. In the

“STANDBY” mode, the “WASH” and “AUTO” functions

are automatically cancelled. The mix refrigeration

function is automatically locked in to maintain the mix

in the hopper.

To resume normal operation, press the “AUTO” button.

When the unit cycles off, the product in the freezing

cylinder will be at serving viscosity. At this time, place

the air tube (end with the hole) into the mix inlet hole

and install the air orifice.

“Wash”

When the “WASH” button is pressed, the light comes

on. This indicates beater motor operation. The

“STANDBY” or “AUTO” modes must be cancelled first

to activate the “WASH” mode.

Note: The Model 336 cannot be operated in

the “WASH” mode if the opposite side of the freezer is

in “AUTO”. Failure to comply with this instruction will

cause the rinse or sanitizing solution to freeze.

“Auto”

When the “AUTO” button is pressed, the light comes

on. This indicates that the main refrigeration system

has been activated. In the “AUTO” mode, the “WASH”

or “STANDBY” functions are automatically cancelled.

The mix refrigeration function is automatically locked

in to maintain the mix in the mix hopper.

Note: An indicating light and an audible tone will

sound whenever a mode of operation has been

pressed. To cancel any function, press the button

again. The light and mode of operation will shut off.