Models 336, 338 & 339

Operating Procedures

Slide the small o-ring into the groove of the air orifice.

Do not lubricate the o-ring.

Figure 19

Note: Make sure the hole in the air orifice is clean and

is not clogged. If the hole in the air orifice should

become clogged, use soap and hot water to clear the

hole.

Do not enlarge the hole in the air orifice.

Install the air orifice into the hole in the top of the air

tube (in the end without the small hole on the side).

Figure 20

Step 11

Lay the air tube (with the air orifice installed) and the

hopper gasket in the bottom of the mix hopper for

sanitizing.

Repeat Steps 10 and 11 for the other side of the

freezer.

Sanitizing

Step 1

Prepare two gallons (7.6 liters) of an approved 100

PPM sanitizing solution (example: Kay-5R). USE

WARM WATER AND FOLLOW THE MANUFACTUR-

ER’S SPECIFICATIONS.

Step 2

Pour the two gallons (7.6 liters) of sanitizing solution

into the hopper and allow it to flow into the freezing

cylinder.

Figure 21

Step 3

While the solution is flowing into the freezing cylinder,

brush clean the mix hopper. When cleaning the

hopper, take particular care in brushing the mix level

sensing probe on the rear wall of the hopper, the mix

inlet hole, the air tube, and the hopper gasket.

Figure 22