17

Models 336, 338 & 339

Operating Procedures

Figure 23

Step 4

Place the power switch in the “ON” position.

Figure 24

Step 5

Press the “WASH” button. This will cause the

sanitizing solution in the freezing cylinder to agitate.

Allow it to agitate for five minutes.

Figure 25

Step 6

Place an empty pail beneath the door spout and raise

the prime plug.

Figure 26

Step 7

When a steady stream of sanitizing solution is flowing

from the prime plug opening in the bottom of the

freezer door, lower the draw handle. Draw off all the

sanitizing solution.

Figure 27

Note: Momentarily pull the center draw handle down

to sanitize the center door spout.

Step 8

Once the sanitizer stops flowing from the door spout,

raise the draw handle and press the “WASH” button,

cancelling the beater motor operation.

Note: You have just sanitized the freezer. Be

sure your hands are sanitized before continuing

these instructions.