19

Models 336, 338 & 339

Operating Procedures

Step 5

Press the “AUTO” button. The “AUTO” light will come

on indicating the main refrigeration system is

operating. When the unit cycles off, the product will be

at serving viscosity.

Figure 32

Note: The mix refrigeration light will come on,

indicating the mix refrigeration system is operating to

maintain the mix in the mix hopper.

Step 6

Fill the hopper with mix. As the mix level comes in

contact with the mix level sensing probe on the rear

wall of the hopper, the “MIX LOW” light will shut off.

Step 7

Place the mix hopper cover in position over the mix

hopper.

Repeat Steps 1 through 7 for the other side of the

freezer.

Closing Procedure

To disassemble your unit, the following items will be

needed:

S

Two cleaning pails

S

Sanitized stainless steel rerun can with lid

S

Necessary brushes (provided with freezer)

S

Cleaner

S

Single service towels

Draining Product From the

Freezing Cylinder

Step 1

Press the “AUTO” button, cancelling compressor and

beater motor operation.
Press the mix refrigeration button, cancelling the mix

hopper refrigeration system.
Step 2

Remove the hopper cover, hopper gasket and air tube.

Take these parts to the sink for cleaning.
Step 3

With a sanitized pail beneath the door spout, press the

“WASH” button. Lower the draw handle and drain the

remaining product from the freezing cylinder and the

mix hopper.
Step 4

When the flow of product stops, press the “WASH”

button, and raise the draw handle. If local health codes

permit, empty the rerun into a sanitized stainless steel

can. Cover the container and place it in the walk-in

cooler.
Repeat Steps 1 through 4 for the other side of the

freezer.
Note: For the Model 336, both sides must be in

WASH. If one side is in AUTO and the other is in

WASH, the side that is in WASH will continue to freeze.

ALWAYS FOLLOW LOCAL HEALTH CODES.

Rinsing

Step 1

Pour two gallons (7.6 liters) of cool clean water into the

mix hopper. With the brushes provided, scrub the mix

hopper, mix inlet hole and mix level sensing probe.
Step 2

With a pail beneath the door spout, raise the prime plug

and press the “WASH” button.
Step 3

When a steady stream of rinse water is flowing from

the prime plug opening in the bottom of the freezer

door, lower the draw handle. Drain all the rinse water

from the freezing cylinder, raise the draw handle and

press the “WASH” button, cancelling the “WASH”

mode.
Repeat Steps 1 through 3 for the other side of the

freezer.