Priming – Carrier 336 User Manual

Page 22

Advertising
background image

18

Models 336, 338 & 339

Operating Procedures

Step 9

Assemble the hopper gasket around the top edge of

the mix hopper. Stand the air tube in the corner of the

hopper.

Figure 28

Repeat Steps 1 through 9 for the other side of the

freezer.

Priming

Step 1

With a pail beneath the door spout, lower the draw

handle. Be sure the prime plug is still in the UP

position. Pour two gallons (7.6 liters) of fresh mix into

the mix hopper and allow it to flow into the freezing

cylinder. This will force out any remaining sanitizing

solution. When full strength mix is flowing from the

door spout, raise the draw handle.

Note: Use only fresh mix when priming the freezing

cylinder.

Figure 29

Step 2

Once a steady stream of mix starts to flow from the

prime plug opening in the bottom of the freezer door,

push down the prime plug.

Figure 30

Step 3

Lubricate the o-rings on the air tube on the end with the

small hole on the side.

Step 4

Install the air tube in the “AUTO” position.

Figure 31

Advertising
This manual is related to the following products:

339, 338