Winter storage – Carrier 336 User Manual

Page 27

Advertising
background image

23

Models 336, 338 & 339

Important: Operator Checklist

j

7. If your machine is equipped with an auxiliary

refrigeration system, check the auxiliary

condenser for accumulation of dirt and lint. Dirty

condensers will reduce the refrigeration

capacity of the mix hopper. Condensers must

be cleaned monthly with a soft brush. Never

use screwdrivers or other metal probes to clean

between the fins.

Caution:

Always

disconnect

electrical power prior to cleaning the

condenser.

j

8. If your machine is water cooled, check the water

lines for kinks or leaks. Kinks can occur when

the machine is moved back and forth for

cleaning

or

maintenance

purposes.

Deteriorated or cracked water lines should be

replaced only by an authorized Taylor

distributor.

Winter Storage

If the place of business is to be closed during the winter

months, it is important to protect the freezer by

following certain precautions, particularly if the

building is subject to freezing conditions.
Disconnect the freezer from the main power source to

prevent possible electrical damage.
On water cooled freezers, disconnect the water

supply. Relieve pressure on the spring in the water

valve. Use air pressure on the outlet side to blow out

any water remaining in the condenser, and then add a

liberal amount of permanent type auto anti-freeze.

This is extremely important. Failure to follow this

procedure may cause severe and costly damage to the

refrigeration system.
Your local Taylor Distributor can perform this winter

storage service for you.
Wrap detachable parts of the freezer such as beater,

blades, drive shaft, and freezer door, and place them

in a protected dry place. Rubber trim parts and gaskets

can

be protected

by

wrapping

them

with

moisture-proof paper. All parts should be thoroughly

cleaned of dried mix or lubrication which attract mice

and other vermin.

Advertising
This manual is related to the following products:

339, 338