Setting the Automatic “Switch-Off” Time (AUTO-OFF)

When the soldering tool is not in use, heating of the soldering tool is

switched off after the AUTO-OFF time has elapsed. The Auto-Off can

be set from 0-999 minutes for each channel independently. With a

setting of "0 min", the Auto Off function is disabled. Auto Off is carried

out independently of the Setback function. The “Read” temperature is

displayed (flashing) and may be monitored as a decreasing heat

indicator; "OFF" appears in the display in small script above the

selected channel. Below 122°F ( 50°C ), a flashing dash appears in

the center of the display.
The following AUTO-OFF time settings are possible:

"0 min“: AUTO-OFF function is switched off

"1-999 min“: AUTO-OFF time, each channel individually selectable

1. Select the menu item OFF in Menu 1.
2. Set the AUTO-OFF Set time with the UP or DOWN Scroll Key.
3. Proceed to the next menu item with the Radio Button ┌ 1 ┐ (back)

or ┌ 2 ┐ (forward) or exit the menu with Radio button ┌ 3 ┐ (EXIT).

Tool Operation with different settings of the SETBACK and AUTO
OFF functions

Settings

SETBACK

Time [1-99

min]

OFF Time [1-

999 min]

Tool Operation without Switching Holder

0
ON

0

Soldering tool remains at the Set soldering temperature.

0
ON

Time

Soldering tool is switched off when not in use

1)

after the OFF time

has elapsed.

Time

0

Soldering tool is controlled down when not in use

1)

to the STANDBY

temperature

2)

after the SETBACK time has elapsed.

Time

Time

Soldering tool is controlled down when not in use

1)

to the STANDBY

temperature

2)

after the SETBACK time has elapsed and is switched

off after the OFF time has elapsed.

Tool Operation with Switching Holder

0

0

Soldering is switched off in the holder

3)

.

ON

0

Soldering tool is controlled to the STANDBY temperature

2)

when in

the holder

3) .

0

Time

Soldering tool is switched off after the OFF time has elapsed when

in the holder

3).

ON

Time

Soldering tool is controlled to the STANDBY temperature

2)

and is

switched off after the OFF time has elapsed when in the holder

3).

Time

0

Soldering tool is controlled to the STANDBY temperature

2)

after the

SETBACK time has elapsed when in the holder

3).

Time

Time

Soldering tool is controlled to the STANDBY temperature

2)

after the

SETBACK time has elapsed and is switched off after the OFF time

has elapsed when in the holder

3).