The Weller WR 3M Rework Station offers the following additional

features / functions:

−

Automatic tool detection and activation of the related control

parameters

−

Operates with all Weller tools listed in the Accessories section on

page 18

−

Digital Temperature Control

−

Temperature Offset

−

Programmable Temperature (Setback)

−

Standby and Lock functions

−

Heavy-duty pump

−

Antistatic device design in accordance with EOS / ESD safety

standards

−

USB port for control, evaluation and documentation via PC

−

Additional vacuum port for component handling (Pick-up)

4.2 WR 3M Technical Data

Dimensions

L x W x H (inches): 10.75 x 9.25 x 4.02

Weight

Approximately. 14.8 lbs.

Power supply voltage

120 VAC, 60 Hz

Power consumption

400 Watts

EOS / ESD Properties

All Tool Handles, Cordsets and Air Flow

are Static Free

Fuse

4 Amp

Temperature Control

range

Variable in (1) degree increments from

150 °F – 999 °F
Controllable temperature range is tool-

dependent

Temperature accuracy

±

17 °F ( Average tip temperature can

be offset ± 9 °F at idle with no load )

Temperature stability

±

9 °F

Hot Air / Vacuum Pump

( duty cycle: 30 seconds

on - 30 seconds off )

Max. vacuum 0.7 bar

Max. delivery rate 18 l/min

Hot air max. 15 l/min

Vacuum Pick-Up Pump

( duty cycle: 60 seconds

on - 30 seconds off )

Max. vacuum 0.5 bar
Max. delivery rate 1.7 l/min

USB Port

The control unit is equipped with a mini USB port (25). Weller

software, included on a CD, provides station monitoring and control

via the USB port.
With the software you;
−

can carry out a software update ("Firmware Updater“) on your

control unit.