The Weller WR 3M Rework Station offers the following additional

features / functions:

Automatic tool detection and activation of the related control

parameters

Operates with all Weller tools listed in the Accessories section on

page 18

Digital Temperature Control

Temperature Offset

Programmable Temperature (Setback)

Standby and Lock functions

Heavy-duty pump

Antistatic device design in accordance with EOS / ESD safety

standards

USB port for control, evaluation and documentation via PC

Additional vacuum port for component handling (Pick-up)

4.2 WR 3M Technical Data

Dimensions

L x W x H (inches): 10.75 x 9.25 x 4.02

Weight

Approximately. 14.8 lbs.

Power supply voltage

120 VAC, 60 Hz

Power consumption

400 Watts

EOS / ESD Properties

All Tool Handles, Cordsets and Air Flow

are Static Free

Fuse

4 Amp

Temperature Control

range

Variable in (1) degree increments from

150 °F – 999 °F
Controllable temperature range is tool-

dependent

Temperature accuracy

±

17 °F ( Average tip temperature can

be offset ± 9 °F at idle with no load )

Temperature stability

±

9 °F

Hot Air / Vacuum Pump

( duty cycle: 30 seconds

on - 30 seconds off )

Max. vacuum 0.7 bar

Max. delivery rate 18 l/min

Hot air max. 15 l/min

Vacuum Pick-Up Pump

( duty cycle: 60 seconds

on - 30 seconds off )

Max. vacuum 0.5 bar
Max. delivery rate 1.7 l/min

USB Port

The control unit is equipped with a mini USB port (25). Weller

software, included on a CD, provides station monitoring and control

via the USB port.
With the software you;

can carry out a software update ("Firmware Updater“) on your

control unit.