Page 6 of 21

WR 3M

can remotely control the unit and chart, store and print temperature

curves ("Monitor Software“).

5 Initial Set-up

WARNING!

Risk of injury may occur if vacuum hose is incorrectly

connected to the air port (15).

If the vacuum hose is incorrectly connected, hot air and liquid

solder can escape when the desoldering button is depressed and

may cause injuries.
Z

Never connect the vacuum hose to the "Air“ port (15)!

1. Carefully unpack the device.
2. Connect the soldering tools as follows:

- Connect the hot-air pencil (HAP200) with air hose to "Air“ port

(15) and insert the (HAP200) plug into the receptacle ┌ 1 ┐,

- (16) of the Rework Station and lock by turning clockwise slightly.

The hot-air pencil (HAP 1) can only be connected with the

supplied air-hose adapter.

Note:

The HAP 200 will only operate when connected to channel 1!

- Connect the Desoldering tool (DXV80) with vacuum hose to

"Vac“ port (14) and insert the (DXV80) tool plug into the

receptacle ┌ 1 ┐, ┌ 2 ┐ or ┌ 3 ┐ (16) of the Rework Station and

lock by turning clockwise slightly.

- Connect the Soldering tool (WP80) with Soldering tool plug into

the receptacle ┌ 1 ┐, ┌ 2 ┐ or ┌ 3 ┐ (16) of the Rework Station

and lock by turning clockwise slightly. If using the optional

(WDH10T) Switching Holder with the Stop and Go feature,

connect the Holder plug to the receptacle ┌ 1 ┐, ┌ 2 ┐ or ┌ 3 ┐

(16) of the Rework Station and the Soldering Tool into the rear

of the Holder.

- Two pick-up tools (WRK, WVP) can be connected with the

vacuum hose to the two pick-up ports (13), where only the right

port is active. It is possible to switch to the other port by rotating

the port 180°.

3. Place the tools in their safety holders.
4. Check the power supply voltage to be sure it matches the rating

on the unit and that the power switch (12) is OFF.

5. Connect the control unit to the power connection (27) on the rear

of the unit and plug in to a properly grounded 120 VAC power

source.

6. Switch ON the WR 3M at the power switch (12).
After the device has been switched ON, the microprocessor carries

out a self-test in which all the segments are briefly displayed. Then

the electronics automatically switches to the basic temperature

setting of 720 °F for all channels and 50% for the "Air" setting. A

green LED (2) above each receptacle lights up when activated

channels are being used: