2. Depress the UP or DOWN Scroll Key. The display switches to the

set value. The temperature symbol (18) flashes.

3. Depress the UP or DOWN Scroll Key to set the desired

temperature:
- Tapping the Scroll Keys changes the Set temperature by one

degree.

- Holding down the Scroll Keys changes the Set temperature

rapidly.

The Set value of the selected channel appears in the display for

approximately 2 seconds after the Scroll Keys are released.

Setting the Pre-set Temperature on Radio Buttons ┌ 1 ┐,┌ 2 ┐ or ┌ 3

The temperature can be set for each channel separately by selecting

three fixed/pre-set Radio Buttons.
1. Select a channel.

Three fixed/pre-set temperatures are shown in the display for

approximately 2 seconds. The temperature can now be Set as

long as the temperature symbol is flashing.

2. Adjust the temperature in the large display with the UP or DOWN

Scroll Keys.

3. Depress the desired Radio Button ┌ 1 ┐, ┌ 2 ┐ or ┌ 3 ┐ for 3

seconds. The temperature display for the corresponding

temperature value flashes during this period. The Set value is

stored after 3 seconds.

4. Release the Radio Button.

Temperature Setting using the Radio Buttons ┌ 1 ┐, ┌ 2 ┐ or ┌ 3 ┐
Factory default settings:
┌ 1 ┐ = 300 °F ( 150 °C ),
┌ 2 ┐ = 660 °F ( 350 °C ),
┌ 3 ┐ = 720 °F ( 380 °C )
1. Select a channel.

Three fixed/pre-set temperatures are shown in the display for

approximately 2 seconds. The temperature can now be Set as

long as the temperature symbol is flashing.

2. The desired fixed/pre-set temperature can now be selected with

Radio Buttons ┌ 1 ┐, ┌ 2 ┐ or ┌ 3 ┐

3. The Set value is adopted. The Read temperature of the selected

channel is displayed after 3 seconds.

6.3 Setting the Air Flow

The Air Flow can, starting from a maximum flow value of 15 l/s (HAP

200) or 10 l/s (HAP 1), be adjusted between 10% to 100%.
1. Depress the AIR button.