9 fault indications and correction, Warning – Weller WR 3M User Manual

Page 17

Advertising
background image

WR 3M

Page 17 of 21

EN

FR

IT

ES

PT

NL

SV

DK

FI

GR

TR

CZ

PL

HU

SK

SL

EE

LV

LT

WARNING!

Vacuum pump will be destroyed if operated without

the filter.

Z

Check to ensure the filters are in place before operating unit.

Replacing the filter

1. Turn the cover cap for "Vac“ (14) or "Air“ (15) 45°

counterclockwise and remove.

2. Pull out the contaminated filter and dispose of properly.
3. Insert an original WELLER filter cartridge.

Make sure that the cover seal is correctly seated.

4. Insert pressure spring.
5. Align the cover cap with slight pressure and turn 45° clockwise.

9 Fault Indications and Correction

Indication/symptom

Possible cause

Corrective Action

Display: "- - -"

Tool has not been detected

Tool defective

Check connection of tool to

device

Check connected tool

HAP 200 does not function

HAP 200 not connected to

channel 1

Connect HAP 200 to channel 1

Display: "tip"

Soldering tip of WMRP

Microtool or WMRT Micro-

Tweezer not correctly inserted

or defective

Insert soldering tip or Tweezer

Cartridge again

Replace defective soldering tip

or Tweezer Cartridge

Pick-up does not function

correctly

Vacuum is not fully built up

Hose defective or kinked

Check vacuum at pick-up

connection

Replace/straighten hose

No air at HAP

Air hose not or incorrectly

connected

Connect air hose to AIR port

No vacuum on Desoldering

tool

Vacuum hose not or

incorrectly connected

Desoldering Tiplet clogged

Desoldering Filter clogged

Connect vacuum hose to Vac

port

Clean Desoldering Tiplet with

cleaning tool

Replace Desoldering Tool

Filter

Status indication of Vac

LED’s incorrect

Vacuum level not correctly set Set vacuum level in special menu

2

No display function (display

off)

No power supply voltage

Turn on power switch

Check power supply voltage

Check device fuse

VAC LED red

Vacuum system clogged

Clean suction nozzle or

replace Desoldering Tiplet

Check filter (13); replace if

clogged

Advertising