WARNING!

Vacuum pump will be destroyed if operated without

the filter.

Z

Check to ensure the filters are in place before operating unit.

Replacing the filter

1. Turn the cover cap for "Vac“ (14) or "Air“ (15) 45°

counterclockwise and remove.

2. Pull out the contaminated filter and dispose of properly.
3. Insert an original WELLER filter cartridge.

Make sure that the cover seal is correctly seated.

4. Insert pressure spring.
5. Align the cover cap with slight pressure and turn 45° clockwise.

9 Fault Indications and Correction

Indication/symptom

Possible cause

Corrective Action

Display: "- - -"

−

Tool has not been detected

−

Tool defective

−

Check connection of tool to

device

−

Check connected tool

HAP 200 does not function

HAP 200 not connected to

channel 1

Connect HAP 200 to channel 1

Display: "tip"

Soldering tip of WMRP

Microtool or WMRT Micro-

Tweezer not correctly inserted

or defective

−

Insert soldering tip or Tweezer

Cartridge again

−

Replace defective soldering tip

or Tweezer Cartridge

Pick-up does not function

correctly

−

Vacuum is not fully built up

−

Hose defective or kinked

−

Check vacuum at pick-up

connection

−

Replace/straighten hose

No air at HAP

Air hose not or incorrectly

connected

Connect air hose to AIR port

No vacuum on Desoldering

tool

−

Vacuum hose not or

incorrectly connected

−

Desoldering Tiplet clogged

−

Desoldering Filter clogged

−

Connect vacuum hose to Vac

port

−

Clean Desoldering Tiplet with

cleaning tool

−

Replace Desoldering Tool

Filter

Status indication of Vac

LED’s incorrect

Vacuum level not correctly set Set vacuum level in special menu

2

No display function (display

off)

No power supply voltage

−

Turn on power switch

−

Check power supply voltage

−

Check device fuse

VAC LED red

Vacuum system clogged

−

Clean suction nozzle or

replace Desoldering Tiplet

−

Check filter (13); replace if

clogged