D.A.S. Audio DASnet V1.5 User Manual

Page 30

Advertising
background image

Preset changes are bidirectional so if a preset is changed on the software it will be also changed
on the cabinet. And vice-versa, a change on the cabinet will be shown as well on the software.

IMPORTANT: all DASnet control parameters (gain, delay, presets, mute, solo...etc) are stored on
the micro controller included in the amplifier. This means that after switching off the system all values
of the parameters will remain the same in memory for the next time the system is switched on.

IMPORTANT: when the user is not sure about the internal settings in the micro controller (delay,
gain etc) the best thing is to do a factory settings reset. Factory settings puts all the parameters
at zero. Device name will remain the same (in this case C15A-2).
Factory settings reset can be done via software: (check that gain and delay are set up at zero)

IMPORTANT: The default or factory settings on the Convert 15A are:

Mode: Point Source
Number of Units: 1 Unit
High Frequency: 0dB
Highpass Filter: OFF

Physically if the user wants to do a reset or factory settings, the control joystick and the display
has to be used:

default factory
settings

OK

OK

OK

OK

Press OK for 2 seconds

By clicking right button select menu
number 2 - utilities

When Restore menu is active
press and hold for 2 seconds

DASnet - 30

Advertising