DASnet - 32

- Load monitoring: for each amplifier channel there is an impedance system control that
indicates if the speakers are working (green) or not (red), as it happens on the other
cabinet models (see Convert 15A or Road series).

On the “advanced view” parameters as gain/delay/preset/polarity/mute and solo are available:

delay control

gain control

presets control

advanced device view window

- Gain control: this control is for the complete cabinet (not per amplifier channel). From -20dB
to +6dB. Value can be entered using the keyboard or the gain control of the software.
- Delay control: this control is for the complete cabinet (not per amplifier channel). From 0ms
to 100ms.

- Polarity: inverts the polarity of the complete cabinet.

- Mute/Solo: per amplifier channel or per cabinet. When SOLO is activated ALL the other
devices on the net are muted.