INSTALLATION INSTRUCTIONS

Fixture Name: AUTUMN TWILIGHT 9903-M1L MG
For Pendant Light Fixture

WARNING! SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER

HANGING THE FIXTUREFig.1

1. Carefully remove the new fixture from the carton and the

yellow bag that holds all parts. Check that all parts are

included as shown in the illustration and parts list.

2. Shut off the power at the circuit breaker and remove old

fixture from ceiling, including the old mounting strap.

3. Thread Nipple(C) into Canopy Loop (F) until snug.

4. Thread other end of the Nipple (C) with Canopy Loop

attached into Mounting Strap (D).

5. Place Lock Washer (B) over end of Nipple (C) protruding

through Mounting Strap (D) and thread Hex Nuts (A) onto

Nipple until tight.

6. Take this mounting strap assembly and mount to ceiling

junction box with junction box Screws (E). Tighten screw

securely with screw driver.

7. Unscrew the Canopy loop collar (H) from the Canopy

loop. Take the canopy and pass over the Canopy loop.

Approximately one half of the canopy loop exterior

threads should be exposed. Adjust until desired height is

reached. *the Canopy loop collar should fit snugly on the

Canopy loop after the canopy is installed. Remove

Canopy and Canopy loop collar.

8. Assemble the fixture and have an assistant or secure

support hold the weight of the fixture while you complete

the wiring connections.

9. Thread the fixture wires and ground wire of the

assembled fixture through the canopy loop (F) and

nipple(C) and chain (every three links) into the outlet box.

CONNECTING THE WIRES (Fig.2)

10. Attach the power supply wires to the fixture lead wires

by connecting BLACK to BLACK (or SMOOTH) and WHITE

to WHITE (or RIBBED).

11. Attach the GROUND wire (GREEN or COPPER) from the

Junction Box and the fixture Ground wire to the green

Ground Screw on the Mounting Bracket (B) or connect

both wires together using the correct size of wire

connectors.

NOTE: Twist the wires together in the same direction you

twist the wire connector onto the wires.

12. Tuck these wire connections neatly into the Junction

Box.

FINISHING THE INSTALLATION (Fig.3)

13. Raise Canopy (G) to the ceiling and secure in place by

tightening the Canopy loop collar (H) into the Canopy

Loop (F).

14. Install the light bulbs and crystals as per the fixture

assembly sheet.

YOUR INSTALLATION IS NOW COMPLETE. TURN POWER ON AT

TO THE JUNCTION BOX & TEST THE FIXTURE.

Fig.1

Fig.2

FIXTURE WIRES

SMOOTH

(or Black)

RIBBED

(or White)

BARE COPPER

(or Green)

HOUSE WIRES

BLACK

(Hot)

WHITE

(Neutral)

GREEN

(Ground)

JUNCTION BOX

(CEILING)

A

B

D

C

E

F

I

I

G

H

CHAIN

J