Chapter 6: Command Sets

GE-DSH-73/DSH-82 and DSH-82-PoE User Manual

155

Commands

Level Description

Example

8021x misc
servertimeout

[sec.]

G

Use the 802.1x misc server
timeout global configuration
command to set the server
timeout.

switch(config)#8021x misc
servertimeout 20

8021x misc maxrequest

[number]

G

Use the 802.1x misc max
request global configuration
command to set the MAX
requests.

switch(config)# 8021x misc
maxrequest 3

8021x misc
reauthperiod

[sec.]

G

Use the 802.1x misc reauth
period global configuration
command to set the reauth
period.

switch(config)# 8021x misc
reauthperiod 3000

8021x portstate

[disable | reject | accept |
authorize]

I

Use the 802.1x port state
interface configuration
command to set the state of
the selected port.

switch(config)#interface fastethernet
3

switch(config-if)#8021x portstate
accept

show 8021x

E

Displays a summary of the
802.1x properties and also
the port sates.

switch>show 8021x

no 8021x

G

Disable 802.1x function

switch(config)#no 8021x