Troubleshooting 175, Appendix b troubleshooting – Interlogix GE-DSH-73 Series User Manual User Manual

Page 179

Advertising
background image

175

Appendix B

Troubleshooting

• Verify that is using the right power cord/adapter (DC 24-48V), please don't use the

power adapter with DC output higher than 48V, or it may damage this device.

• Select the proper UTP/STP cable to construct the user network. Use unshielded

twisted-pair (UTP) or shield twisted-pair (STP) cable for RJ-45 connections that
depend on the connector type the switch equipped: 100O Category 3, 4 or 5 cable
for 10Mbps connections, 100O Category 5 cable for 100Mbps connections, or
100O Category 5e/above cable for 1000Mbps connections. Also be sure that the
length of any twisted-pair connection does not exceed 100 meters (328 feet).

• Diagnosing LED Indicators: To assist in identifying problems, the switch can be

easily monitored through panel indicators, which describe common problems the
user may encounter and where the user can find possible solutions.

• If the power indicator does not light on when the power cord is plugged in, you

may have a problem with power cord. Then check for loose power connections,
power losses or surges at power outlet. If you still cannot resolve the problem,
contact the local dealer for assistance.

• If the LED indicators are normal and the connected cables are correct but the

packets still cannot be transmitted. Please check the user system's Ethernet
devices' configuration or status