There are 8 wires on a standard UTP/STP cable and each wire is color-coded. The
following shows the pin allocation and color of straight cable and crossover cable
connection:

Figure A-1: Straight-Through and Crossover Cable

Straight Cable

SIDE 1

SIDE2

SIDE 1

1

1

2

2

3

3

4

4

5

5

6

6

7

7

8

8

SIDE 2

1 = White / Orange
2 = Orange
3 = White / Green
4 = Blue
5 = White / Blue
6 = Green
7 = White / Brown
8 = Brown

1 = White / Orange
2 = Orange
3 = White / Green
4 = Blue
5 = White / Blue
6 = Green
7 = White / Brown
8 = Brown

Crossover Cable

SIDE 1

SIDE2

SIDE 1

1

1

2

2

3

3

4

4

5

5

6

6

7

7

8

8

SIDE 2

1 = White / Orange
2 = Orange
3 = White / Green
4 = Blue
5 = White / Blue
6 = Green
7 = White / Brown
8 = Brown

1 = White / Green
2 = Green
3 = White / Orange
4 = Blue
5 = White / Blue
6 = Orange
7 = White / Brown
8 = Brown

Please make sure your connected cables are with same pin assignment and color as
above picture before deploying the cables into your network.