Interlogix GE-DSH-73 Series User Manual User Manual

Page 62

Advertising
background image

Chapter 5: Web-Based Management

58

GE-DSH-73/DSH-82 and DSH-82-PoE User Manual

This page includes the following fields:

Object

Description

System event selection:

There are 4 event types—Device Cold Start, Device Warm Start,
Authentication Failure, and X-ring Topology Change. The
checkboxes are not available for ticking unless the Syslog Client
Mode on the Syslog Configuration tab and the E-mail Alert on the
SMTP Configuration tab are enabled first.

Device cold start: When the device executes cold start action, the
system will issue the event log/email alert to the system log/SMTP
server respectively.

Device warm start: When the device executes warm start, the
system will issue the event log/email alert to the system log/SMTP
server respectively.

Authentication Failure: When the SNMP authentication fails, the
system will issue the event log/email alert to the system log/SMTP
server respectively.

X-ring topology change: When the X-ring topology has changed, the
system will issue the event log/email alert to the system log/SMTP
server respectively.

Port event selection:

Also, before the drop-down menu items are available, the Syslog
Client Mode selection item on the Syslog Configuration tab and the
E-mail Alert selection item on the SMTP Configuration tab must be
enabled first. Those drop-down menu items have 3 selections—Link
UP, Link Down, and Link UP & Link Down. Disable means no event
will be sent to the system log/SMTP server.

Link UP: The system will only issue a log message when the link-up
event of the port occurs.

Link Down: The system will only issue a log message when the link-
down event of port occurs.

Link UP & Link Down: The system will issue a log message at the
time when port connection is link-up and link-down.


Advertising
This manual is related to the following products: