Rs-485 ports, Rs-232 port, Monitor connections – Interlogix NVR 50 User Manual User Manual

Page 14: Audio inputs and output

Advertising
background image

1BChapter 2: Installation

8

TruVision NVR 50 User Manual

RS-485 ports

There are two RS-485 ports on the rear panel of the NVR. See Figure 5 below for
the serial pin outs.

Dome RS-485:

A and B: Connect pan, tilt, zoom control of PTZ dome cameras. A = +, B = -

C and D: Not used

G: Ground of dome camera

G: Ground of keypad

Keyb: Connect the keypad.

Figure 5: RS-485 pins

RS-232 port

Use the RS-232 port to connect CBR-PB3-POS (point-of-sale) and ATM devices
to the NVR.

Monitor connections

Connect the unit to a monitor via a 75-ohm video coaxial cable with the BNC
connector. The unit provides a 1 Vp-p CVBS signal. See Figure 1 on page 5 for
connecting a monitor to a TVN 50.

The TVN 50 supports up to 1920 × 1080 / 60 Hz resolution in VGA. The monitor
resolution should be at least 800 × 600. Adjust your monitor accordingly to this
resolution.

Audio inputs and output

The unit is equipped with 1 audio input and two audio outputs. Both the audio
outputs and the audio inputs are line-level.

Advertising