Viii, Programming locations – Interlogix NX-1710E User Manual

Page 11

Advertising
background image

NX-1710E Single Door Control

11

D

ELETE

/ R

ESET

O

NE

U

SER

[

EXIT

]

Accesses De-activation mode

[

3-digit user number

]

Example:

if 4-digit user code or

if 6-digit

If a valid user number is entered, LED1
(Green) on any enabled readers will begin
to flash.

Scan any card

The card information for the user entered
in the previous step will be cleared, and
LED1 (Green) will stop flashing. After
about 30 seconds, all the readers in the
system will be updated.


VIII.

PROGRAMMING LOCATIONS

For the purpose of these instructions, the term “door control” refers to the NX-1710E

module, and the term “reader” refers to the specific card reader attached to the
system.

L

OCATION

0 R

EADER

“A” S

CAN

F

UNCTIONS

& O

PTIONS

(8 segments of binary data) Location 0 is used to select the particular function(s) that are activated when a card
is scanned at Reader “A”. More than one function may be selected. If more than one function is selected, they
will execute in order from function 1 to function 8.

Functions 1-6 will be performed based on the user’s authority as programmed by the [ ] [6]

function (refer to keypad user manual).

Segment 1

Single Scan Function

Program the functions that are performed when a card is scanned {one beep}.

LED1 -

"On" to send Code Entry function to the control panel.

LED2 -

"On" to activate the Armed Away mode.

LED3 -

"On" to activate the Armed Stay mode.

LED4 -

"On" to send the Disarm function to the control panel.

LED5 -

"On" to send Auxiliary Function #1 to the control panel.

LED6 -

"On" to send Auxiliary Function #2 to the control panel.

LED7 -

"On" to broadcast an X-10 function (see Location 241 for programming).

LED8 -

"On" to send a Request-to-Exit (RTE) and to activate the onboard relay. (Default is
“On”)

Segment 2

Triple Scan Function

Program the functions that are performed when a card is scanned three times {three beeps}. The descriptions
of the options are the same as for Single Scan Function (Segment 1 above). Default is 1.

Segment 3

Reader Options:

LED1 -

"On" if tamper is inverted.

LED2 -

"On" if tamper is enabled.

LED3 -

"On" if reader buzzer is to follow typical keypad buzzing.

LED4 -

"On" if reader automatically issues a beep when the card is scanned. Enabling
this option prevents the door control from issuing another beep. (Default is “On”)

LED5–8

Reserved.

If an individual keeps the card, it can still be deleted.