Interlogix NX-1710E User Manual

Page 18

Advertising
background image

NX-1710E Single Door Control

18

USER-DEFINABLE FORMATS

The following locations are considered to be advanced programming and should

ONLY be used by installers with a thorough understanding of Weigand Formats. Do
not attempt to program these locations if you are not familiar with Weigand packets.

L

OCATION

45

WEIGAND FORMAT 1

(S

TANDARD

26

BIT

)

– D

IGITS

& B

ITS

(5 segments of decimal data) This is the first location used to program the Weigand Format 1. (Loc 45-57)

Segment 1

Number of digits in Facility Code

Segment 2

Number of digits in Badge Number

Segment 3

Number of bits in Facility Code

Segment 4

Number of bits in Badge Number

Segment 5

Total number of bits in complete format (including parity bits)

L

OCATION

46

WEIGAND FORMAT 1 – B

IT

D

ESCRIPTORS

(B

ITS

1-32)

(32 segments of hex data) This location contains the descriptors for bits 1 – 32 of Weigand Format 1. The
available options are: 0=Always Zero; 1=Always One; B=Badge number; D=Parity bit; E=End of
format; F=Facility Code bit.
Segment 1 = Bit Descriptor 1; Segment 32 = Bit Descriptor 32.

L

OCATION

47

WEIGAND FORMAT 1 – B

IT

D

ESCRIPTORS

(B

ITS

33-64)

(32 segments of hex data) This location contains the descriptors for bits 33 – 64 of Weigand Format 1.
The available options are: 0=Always Zero; 1=Always One; B=Badge number; D=Parity bit; E=End of
format; F=Facility Code bit.
Segment 1 = Bit Descriptor 33; Segment 32 = Bit Descriptor 64.

L

OCATION

48

WEIGAND FORMAT 1 – P

ARITY

T

YPE

1

(1 segment of decimal data) This location programs the Partity Type 1 for Weigand Format 1. Available options
for this location are 0 = No Parity; 1 = Odd Parity; 2 = Even Parity. Factory default is 1.

L

OCATION

49

WEIGAND FORMAT 1 – P

ARITY

M

ASK

1

(8 segments of binary data) This location tells which bits to include for the parity count; and includes the parity
bits. It is used in conjunction with Location 48 (Parity Type 1). The factory default is:

Seg 1

Seg 2

Seg 3

Seg 4

Seg 5

Seg 6

Seg 7

Seg 8

12345678

12345678

12345678

------78

-------- -------- -------- --------

L

OCATION

50

WEIGAND FORMAT 1 – P

ARITY

T

YPE

2

(1 segment of decimal data) This location programs the Partity Type 2 for Weigand Format 1. Available options
for this location are 0 = No Parity; 1 = Odd Parity; 2 = Even Parity. Factory default is 2.

L

OCATION

51

WEIGAND FORMAT 1 – P

ARITY

M

ASK

2

(8 segments of binary data) This location tells which bits to include for the parity count; and includes the parity
bits. It is used in conjunction with Location 50 (Parity Type 2). The factory default is:

Seg 1

Seg 2

Seg 3

Seg 4

Seg 5

Seg 6

Seg 7

Seg 8

12345678

---45678

--------

--------

-------- -------- -------- --------

L

OCATION

52

WEIGAND FORMAT 1 – P

ARITY

T

YPE

3

(1 segment of decimal data) This location programs the Partity Type 3 for Weigand Format 1. Available options
for this location are 0 = No Parity; 1 = Odd Parity; 2 = Even Parity. Factory default is 0.

L

OCATION

53

WEIGAND FORMAT 1 – P

ARITY

M

ASK

3

(8 segments of binary data) This location tells which bits to include for the parity count; and includes the parity
bits. It is used in conjunction with Location 52 (Parity Type 3). The factory default is:

Seg 1

Seg 2

Seg 3

Seg 4

Seg 5

Seg 6

Seg 7

Seg 8

--------

--------

--------

--------

-------- -------- -------- --------

Advertising