Weigand format 4 – Interlogix NX-1710E User Manual

Page 28

Advertising
background image

NX-1710E Single Door Control

28

LOCATION 73 – WIEGAND FORMAT 3 (BIT DESCRIPTOR 33 - 64)

0 = Always Zero; 1 = Always One; B = Badge Number Bit; D = Parity Bit; E = End of Format; F = Facility Code Bit

SEG

DESCRIPTION DEFAULT

DATA SEG

DESCRIPTION DEFAULT

DATA

1

Bit 33 Descriptor

B

17

Bit 49 Descriptor

E

2

Bit 34 Descriptor

B

18

Bit 50 Descriptor

E

3

Bit 35 Descriptor

D

19

Bit 51 Descriptor

E

4

Bit 36 Descriptor

E

20

Bit 52 Descriptor

E

5

Bit 37 Descriptor

E

21

Bit 53 Descriptor

E

6

Bit 38 Descriptor

E

22

Bit 54 Descriptor

E

7

Bit 39 Descriptor

E

23

Bit 55 Descriptor

E

8

Bit 40 Descriptor

E

24

Bit 56 Descriptor

E

9

Bit 41 Descriptor

E

25

Bit 57 Descriptor

E

10

Bit 42 Descriptor

E

26

Bit 58 Descriptor

E

11

Bit 43 Descriptor

E

27

Bit 59 Descriptor

E

12

Bit 44 Descriptor

E

28

Bit 60 Descriptor

E

13

Bit 45 Descriptor

E

29

Bit 61 Descriptor

E

14

Bit 46 Descriptor

E

30

Bit 62 Descriptor

E

15

Bit 47 Descriptor

E

31

Bit 63 Descriptor

E

16

Bit 48 Descriptor

E

32

Bit 64 Descriptor

E

LOCATION 74 – WIEGAND FORMAT 3 (PARITY TYPE 1)

0=No Parity; 1=Odd Parity; 2=Even Parity

1

Parity Type 1

1

LOCATION 75 – WIEGAND FORMAT 3 (PARITY MASK 1)

1

Parity Mask 1

12345678

5

Parity Mask 5

-----678

2

Parity Mask 2

12345678

6

Parity Mask 6

--------

3

Parity Mask 3

12345678

7

Parity Mask 7

--------

4

Parity Mask 4

12345678

8

Parity Mask 8

--------

LOCATION 76 – WIEGAND FORMAT 3 (PARITY TYPE 2)

0=No Parity; 1=Odd Parity; 2=Even Parity

1

Parity Type 2

1

LOCATION 77 – WIEGAND FORMAT 3 (PARITY MASK 2)

1

Parity Mask 1

1-34-67-

5

Parity Mask 5

-----6-8

2

Parity Mask 2

-23-56-8

6

Parity Mask 6

--------

3

Parity Mask 3

12-45-78

7

Parity Mask 7

--------

4

Parity Mask 4

1-34-67-

8

Parity Mask 8

--------

LOCATION 78 – WIEGAND FORMAT 3 (PARITY TYPE 3)

0=No Parity; 1=Odd Parity; 2=Even Parity

1

Parity Type 3

2

LOCATION 79 – WIEGAND FORMAT 3 (PARITY MASK 3)

1

Parity Mask 1

-23-567-

5

Parity Mask 5

------78

2

Parity Mask 2

12-45-78

6

Parity Mask 6

--------

3

Parity Mask 3

1-34-67-

7

Parity Mask 7

--------

4

Parity Mask 4

-23-56-8

8

Parity Mask 8

--------

LOCATION 80 – WIEGAND FORMAT 3 (PARITY TYPE 4)

1

Parity Type 4

0

LOCATION 81 – WIEGAND FORMAT 3 (PARITY MASK 4)

1

Parity Mask 1

--------

5

Parity Mask 5

--------

2

Parity Mask 2

--------

6

Parity Mask 6

--------

3

Parity Mask 3

--------

7

Parity Mask 7

--------

4

Parity Mask 4

--------

8

Parity Mask 8

--------

LOCATION 82 – WIEGAND FORMAT 3 (PARITY TYPE 5)

1

Parity Type 5

0

LOCATION 83 – WIEGAND FORMAT 3 (PARITY MASK 5)

1

Parity Mask 1

--------

5

Parity Mask 5

--------

2

Parity Mask 2

--------

6

Parity Mask 6

--------

3

Parity Mask 3

--------

7

Parity Mask 7

--------

4

Parity Mask 4

--------

8

Parity Mask 8

--------

WEIGAND FORMAT 4

LOCATION 84 – WIEGAND FORMAT 4 (DIGITS & BITS) (DECIMAL DATA)

DESCRIPTION

DEFAULT

DATA

1

Number of Digits in Facility Code

5

2

Number of Digits in Badge Number

6

3

Number of Bits in Facility Code

16

4

Number of Bits in Badge Number

19

5

Total Number of Bits in Complete Weigand
Format (including parity bits)

37