NX-1710E Single Door Control

21

SEG

DESCRIPTION

5 LED2 (RED) OPTIONS

1

=

"On" to follow Armed status of system.

2 = "On" to toggle with the relay activation.
3 = "On" if inverted.
4-8 Reserved.

6-8 RESERVED

LOCATION 2 – X10 ADDRESS

1 MODULE NUMBER

0

=

Module 1

1 = Module 2
2 = Module 3
3 = Module 4

4 = Module 5
5 = Module 6
6 = Module 7
7 = Module 8

8 = Module 9
9 = Module 10
10 = Module 11
11 = Module 12

12 = Module 13
13 = Module 14
14 = Module 15
15 = Module 16

2 HOUSE CODE

0

=

A

1 = B
2 = C
3 = D

4 = E
5 = F
6 = G
7 = H

8 = I
9 = J
10 = K
11 = L

12 = M
13 = N
14 = O
15 = P

3 READER “A” SINGLE SCAN

0 = All units off
1 = All lights on

2 = On
3 = Off

4 = Dim
5 = Bright

6 = All lights off
7 = All others = Reserved

4 READER “A” TRIPLE SCAN

0 = All units off
1 = All lights on

2 = On
3 = Off

4 = Dim
5 = Bright

6 = All lights off
7 = All others = Reserved

5 READER “B” SINGLE SCAN

0 = All units off
1 = All lights on

2 = On
3 = Off

4 = Dim
5 = Bright

6 = All lights off
7 = All others = Reserved

6 READER “B” TRIPLE SCAN

0 = All units off
1 = All lights on

2 = On
3 = Off

4 = Dim
5 = Bright

6 = All lights off
7 = All others = Reserved

LOCATION 3 – OPTIONS & DOOR CONTROL PARTITION

1 UNIT OPTIONS

1 =

"On" if enabled for User Card Programming

2 =

"On" if tamper enabled

3 =

"On" if on-board zone is disabled

4 =

Reserved.

5 =

“On” if an RTE from a scanned card is to be logged as Code Entry

6 =

“On” if an RTE from a zone or the egress input is to be logged as Code Entry

7-8 =

Reserved

2 DOOR OPTIONS

1 =

"On" if locking mechanism is a Maglock or Drop Bolt.

2 =

"On" if access is allowed regardless of Armed status of the system.

3 =

"On" if the door is not to be latched unlocked during an open schedule.

4 =

"On" if onboard relay only triggers during an open schedule.

5 =

“On” if onboard relay only triggers during a close schedule.

6 =

“On” if Forced Entry Alarm is logged.

7 =

“On” if access allowed without an RTE.

8 =

“On” if relay operates normally during off-schedule (

outside of regular operating hours

).

3 ENABLING THE SCHEDULES FOR THE ONBOARD RELAY

1 =

"On" if driver follows Schedule 1.

2 =

"On" if driver follows Schedule 2.

3 =

"On" if driver follows Schedule 3.

4 =

"On" if driver follows Schedule 4.

5 =

"On" if driver follows Schedule 5.

6 =

"On" if driver follows Schedule 6.

7 =

"On" if driver follows Schedule 7.

8 =

"On" if driver follows Schedule 8.

4 READER PARTITION

1 =

"On" if door control is in Partition 1

2 =

"On" if door control is in Partition 2

3 =

"On" if door control is in Partition 3

4 =

"On" if door control is in Partition 4

5 =

"On" if door control is in Partition 5

6 =

"On" if door control is in Partition 6

7 =

"On" if door control is in Partition 7

8 =

"On" if door control is in Partition 8