Interlogix NX-1710E User Manual

Page 19

Advertising
background image

NX-1710E Single Door Control

19

L

OCATION

54

WEIGAND FORMAT 1 – P

ARITY

T

YPE

4

(1 segment of decimal data) This location programs the Partity Type 4 for Weigand Format 1. Available options
for this location are 0 = No Parity; 1 = Odd Parity; 2 = Even Parity. Factory default is 0.

L

OCATION

55

WEIGAND FORMAT 1 – P

ARITY

M

ASK

4

(8 segments of binary data) This location tells which bits to include for the parity count; and includes the parity
bits. It is used in conjunction with Location 54 (Parity Type 4). The factory default is:

Seg 1

Seg 2

Seg 3

Seg 4

Seg 5

Seg 6

Seg 7

Seg 8

--------

--------

--------

--------

-------- -------- -------- --------

L

OCATION

56

WEIGAND FORMAT 1 – P

ARITY

T

YPE

5

(1 segment of decimal data) This location programs the Partity Type 5 for Weigand Format 1. Available options
for this location are 0 = No Parity; 1 = Odd Parity; 2 = Even Parity. Factory default is 0.

L

OCATION

57

WEIGAND FORMAT 1 – P

ARITY

M

ASK

5

(8 segments of binary data) This location tells which bits to include for the parity count; and includes the parity
bits. It is used in conjunction with Location 56 (Parity Type 5). The factory default is:

Seg 1

Seg 2

Seg 3

Seg 4

Seg 5

Seg 6

Seg 7

Seg 8

--------

--------

--------

--------

-------- -------- -------- --------

L

OCATIONS

58 – 70

WEIGAND FORMAT 2

(T

ECOM

ASC 27

BIT

)

These locations contain the programming for Weigand Format 2. Refer to the instructions for Locations 45 – 57
regarding the Bit Descriptors, Parity Types and Parity Masks 1-5. Factory defaults are in the worksheets.

L

OCATIONS

71 - 83

WEIGAND FORMAT 3

(HID1000)

These locations contain the programming for Weigand Format 3. Refer to the instructions for Locations 45 – 57
regarding the Bit Descriptors, Parity Types and Parity Masks 1-5. Factory defaults are in the worksheets.

L

OCATIONS

84 – 96

WEIGAND FORMAT 4

(H10304)

These locations contain the programming for Weigand Format 4. Refer to the instructions for Locations 45 – 57
regarding the Bit Descriptors, Parity Types and Parity Masks 1-5. Factory defaults are in the worksheets.

L

OCATIONS

97 - 109

WEIGAND FORMAT 5

(40

BIT W

/F

ACILITY CODE

C

ASI

4001)

These locations contain the programming for Weigand Format 5. Refer to the instructions for Locations 45 – 57
regarding the Bit Descriptors, Parity Types and Parity Masks 1-5. Factory defaults are in the worksheets.

L

OCATIONS

110 - 122

WEIGAND FORMAT 6

(40

BIT W

/

O

F

ACILITY CODE

C

ASI

4002)

These locations contain the programming for Weigand Format 6. Refer to the instructions for Locations 45 – 57
regarding the Bit Descriptors, Parity Types and Parity Masks 1-5. Factory defaults are in the worksheets.

L

OCATIONS

123 - 135

WEIGAND FORMAT 7

(U

NDEFINED

)

These locations contain the programming for Weigand Format 7. Refer to the instructions for Locations 45 – 57
regarding the Bit Descriptors, Parity Types and Parity Masks 1-5. Factory defaults are in the worksheets.

L

OCATIONS

136 - 148

WEIGAND FORMAT 8

(U

NDEFINED

)

These locations contain the programming for Weigand Format 8. Refer to the instructions for Locations 45 – 57
regarding the Bit Descriptors, Parity Types and Parity Masks 1-5. Factory defaults are in the worksheets.

Advertising