Interlogix TruPortal User Manual

Page 109

Advertising
background image

TruPortal Software User Guide

97

Diagnostics

An ellipsis (...) appears if additional information about a category is available in a tool tip that
can be displayed by hovering over the ellipsis.

The System does not include actions for running specific diagnostic tests.

Click [Download Diagnostic File] to create a single, encrypted file that includes a variety of
system information, including configuration data and logs. No specific personnel information
(for example, names or Social Security numbers) will be included in the file; refer to the Release
Notes for details. The file can be saved locally and sent to Technical Support for use in
troubleshooting issues.

An accurate reading for DC current cannot be displayed when the System Controller is powered
by a DC source. The DC current information is only displayed when the System Controller has
AC power.

Diagnostic

Display Value

Status

AC Power

OK | Brownout | Fail

INF = OK

WRN = Brownout

ERR = Fail

DC Power

Voltage, Current

INF >= 10.0

VWRN < 10.0 V

WRN = Current overload

Backup Battery

Voltage, Current, Charging | Discharging

INF >= 11.7

VWRN < 11.7 V

ERR < 11.4 V, No Battery

Memory Battery

Voltage

INF >= 2.3 V

WRN < 2.3 V

ERR < 2.0 V

Fuses

OK | Fuse Name,…

INF = All OK

ERR = If any not OK

Controller

OK | Problems,…

INF = OK

WRN = If not OK

Modules

OK | ModuleName problem,…

INF = All OK

WRN = If any tamper

ERR = If any offline

Doors

OK | DoorName problem,…

INF = All OK

WRN = If any held,
forced, tamper

ERR – If any offline

Digital Inputs

OK | InputName problem,…

INF = All OK

WRN = If any tamper

ERR – If any offline

Uptime

Last boot time, up days

INF = Always

CPU Load Avg

1m, 5m, 15m

INF 15m < 0.80

WRN 15m >= 0.80

ERR 15m >= 0.95