Contec SPI-8450-LLVA User Manual

Page 116

Advertising
background image

CHAPTER 8 - BIOS Setup

SPI-8450-LLVA

109

PLEASE RUN EISA CONFIGURATION UTILITY

The EISA non-volatile RAM checksum is incorrect or cannot correctly read the EISA slot. This

can indicate either the EISA non-volatile memory has become corrupt or the slot has been

configured incorrectly. Also be sure the card is installed firmly in the slot.

EISA configuration is not complete

PLEASE RUN EISA CONFIGURATION UTILITY

The slot configuration information stored in the EISA non-volatile memory is incomplete.

Note: When either of these errors appear, the system will boot in ISA mode,
which allows you to run the EISA Configuration Utility.

Error encountered initializing hard drive

Hard drive cannot be initialized. Be sure the adapter is installed correctly and all cables are

correctly and firmly attached. Also be sure the correct hard drive type is selected in Setup.

Error initializing hard disk controller

Cannot initialize controller. Make sure the cord is correctly and firmly installed in the bus. Be

sure the correct hard drive type is selected in Setup. Also check to see if any jumper needs to be

set correctly on the hard drive.

Floppy disk controller error or no controller present

Cannot find or initialize the floppy drive controller. Make sure the controller is installed

correctly and firmly. If there are no floppy drives installed, be sure the Diskette Drive selection

in Setup is set to NONE.

Invalid EISA configuration

Advertising