CHAPTER 8 - BIOS Setup

110

SPI-8450-LLVA

PLEASE RUN EISA CONFIGURATION UTILITY

The non-volatile memory containing EISA configuration information was programmed

incorrectly or has become corrupt. Re-run EISA configuration utility to correctly program the

memory.

NOTE: When this error appears, the system will boot in ISA mode, which
allows you to run the EISA Configuration Utility.

Keyboard error or no keyboard present

Cannot initialize the keyboard. Make sure the keyboard is attached correctly and no keys are

being pressed during the boot.

If you are purposely configuring the system without a keyboard, set the error halt condition in

Setup to HALT ON ALL, BUT KEYBOARD. This will cause the BIOS to ignore the missing

keyboard and continue the boot.

Memory address error at ...

Indicates a memory address error at a specific location. You can use this location along with the

memory map for your system to find and replace the bad memory chips.

Memory parity error at ...

Indicates a memory parity error at a specific location. You can use this location along with the

memory map for your system to find and replace the bad memory chips.

Memory size has changed since last BOOT

Memory has been added or removed since the last boot. In EISA mode use Configuration

Utility to reconfigure the memory configuration. In ISA mode enter Setup and enter the new

memory size in the memory fields.

Memory verify error at ...

Indicates an error verifying a value already written to memory. Use the location along with your

system's memory map to locate the bad chip.

Offending address not found

This message is used in conjunction with the I/O CHANNEL CHECK and RAM PARITY

ERROR messages when the segment that has caused the problem cannot be isolated.