background image

CHAPTER 6 - RAID Controller

48

SPI-8450-LLVA

FastBuild (tm) Utility 1.xx (c) 1996-2001 Promise Technology, Inc.

[ Rebuild Array Menu ]

Array No RAID Mode Total Drv Capacity(MB) Status
Array 1 Mirror 2 16126 Critical
Array 2 —— —— —— ——
Array 3 —— —— —— ——
Array 4 —— —— —— ——

[ Keys Available ]

[

↑] Up [↓] Down [ESC] Exit [Enter] Select

9.

Highlight the array whose Status is Critical.

10. Press [Enter]. The following screen will then appear.

FastBuild (tm) Utility 1.xx (c) 1996-2001 Promise Technology, Inc.

[ Rebuild Array Menu ]

Array No

RAID Mode Total Drv

Status

Array 2

Mirror

2

Critical


Stripe Block: Not Available

[ Select Drive for Rebuild ]

Channel:ID Drive Model

Capacity (MB)

1 : Slave

QUANTUMCR8.4A

8063

[ Keys Available ]

[

↑] Up [↓] Down [ESC] Exit [Enter] Select

11. Under [Select Drive for Rebuild], highlight the replacement drive.
12. Press [Enter] and confirm that the data will be copied on to the selected drive. All data on

the replacement drive will be written over with mirrored information from the array drive.
A progress bar will appear as below.

Please Wait While Duplicating The Image
10% Complete

13. Once the rebuild process is complete, the user will be asked to reboot the system.

Advertising