Initial Configuration of the Switch

2-4

Modular SAN Array Fabric Switch 6 User Guide

COMPAQ CONFIDENTIAL

Writer: Kim L. Miller File Name: c-ch2 Initial Configuration of the Switch.doc

Codename: Millebourne Part Number: 230934-002 Last Saved On: 7/17/02 7:46 AM

5. Set up the properties for the terminal connection.

In Windows NT 4.0:

a. Double-click the Hypertrm icon.

b. Enter a name for the connection in the New Connection dialog box, select an

icon to represent the switch for future use, and click OK.

The Connect To dialog box is displayed.

6. From the Connect using drop-down menu, select the communications port

assigned to the serial port (for example, COM1, COM2) and click OK. In the
properties dialog box, enter the following port settings and select OK.

Table 2-1: Default Serial Port Settings

Type Setting

Bits per second (baud rate)

38,600

Data bits

8

Parity None

Stop bits

1

Flow control

None

7. Select File Properties to show the connection properties dialog box. Select the

Settings tab. From the Emulation pull-down menu, select VT100 and click OK.

8. Power ON all peripheral device(s).

9. Wait at least ten seconds and power cycle the MSA1000. The switch sends a

series of Power-on Self-Test (POST) messages in HyperTerminal.